Controlled Products Systems Group HRG 220-A ST User Manual
Page 46

Installation and Maintenance Manual
32
Description of Functions Available in the Installer Menu
Installer 16 [Sr 1] IES (inherent sensor) reverse to open: The default for this menu item is for a 2
second reversal if the inherent sensor is triggered. The optional setting of [Sr_1] will cause the gate to
reopen fully if triggered while closing.
Installer 17 [PC 0] Set PEO/ PEC
– NO/NC: The default for this menu item is for photo eyes with Normally
Open outputs. The optional setting of [PC_1] will require a Normally Closed output. If set for N.C. the
connection is also supervised and any open or short circuit fault will generate a FAL2 alert, which requires a
Stop button reset to re-enable any function if triggered.
Installer 18 [gC 0] Set Edge input
– NO/NC: The default for this menu item is for edge sensor with
Normally Open outputs. The optional setting of [gC_1] will require a N.C. output.
Installer 19 [tC 1] Time clock / Interlock input: This menu item configures the input at terminal #7 to be
either for the gate interlock function, or for an external time clock to open input. The default setting is [tC_1]
for the interlock function.
Installer 20
[dt 0]
Disable Free Exit / Close timer:
This input configures the input at terminal #9 to disable
either the Free Exit Detector on terminal #8, or the Timer To Close function. Default setting is [dt 0] allowing
disabling of the free exit detector.
Installer 21 [or 1] OOLD (Outside Obstruction loop detector) function: The default for this menu item is
for full reversal when the OOLD is triggered. The optional setting [or_0] causes the gate to only pause when
triggered. Closure begins as soon as the loop is clear again.
Installer 22 [ir 1] IOLD (Inside Obstruction loop detector) function: The default for this menu item is for
full reversal when the IOLD is triggered. The optional setting [ir_0] causes the gate to only pause when
triggered. Closure begins as soon as the loop is clear again.
Installer 23 [hd 1] SLD (Shadow loop detector) function: The default for this menu item allows the
shadow loop to prevent the swing gate from opening if triggered. The optional setting [hd_0] causes the
shadow loop to only prevent closure of the gate.
Installer 24 [dL 1] Vehicle detector logic: This menu item is used to configure quick close logic. For swing
gates, there are two modes. Mode 1 is standard logic. Mode 2 allows a faster closure by allowing the close
timer to count down even when a detector loop is active.
Installer 25, 26, 27 [r1 0], [r2 0], [r3 0] User output relays 1 - 3 programming options: These three
menu items are used to configure the function of the three user output relays. There are 19 optional choices,
which are described in detail in Options for User Programmable Output Relays 1-3.
Installer 28 [t L 0] Gate Open alert: This menu item is to adjust the time delay before activating the user
relay function #8, described in Options for User Programmable Output Relays 1-3. Time settings up to 135
seconds.
Installer 29 [Lt 0] Loitering alert: This menu item is to adjust the time delay before activating the user
relay function #13, described in Options for User Programmable Output Relays 1-3.Time settings up to 135
seconds.
Installer 30
[SA 0]
System Address:
Set the system address for network communication. 0 = no network
communication, 1-99 set individual poling addresses. Requires v4.24 software or higher.
Installer 31 [ELd0] Factory ELD: Controls the HY-5A Free Exit detector.
Installer 32 [iLd0] Factory IOLD: Controls the HY-5A IOLD detector.
Installer 33 [oLd0] Factory OOLD: Controls the HY-5A OOLD detector.
Installer 34 [SLd0] Factory SLD: Controls the HY-5A Shadow detector. Refer to Detector & Loop Fault
Diagnostics.