Controlled Products Systems Group HRG 220-A ST User Manual
Page 43
Installation and Maintenance Manual
29
Smart Touch Controller Installer Menu Functions
The Installer Menu can be accessed only by entering the User Menu first, and then by pressing the
Reset button and the Open button simultaneously.
To restore the factory default settings, go to menu item [Fd_0] and change the setting to 1, then press
the Program Menu button. The entire menu will reset to the factory defaults.
Installer Menu Options
Default
Description
I1
[uC 0] Set UL Usage Class
0
0 = Gate disabled, Set Class 1 through 4 use
I2
[bu 0] Choose Buzzer
0
0 = Buzzer not set, 1 = Freq 1, 2 = Freq. 2
I3
[Fd 0] Load Factory Defaults
0
0 = User settings, 1 = Load defaults (resets full menu)
I4
[dg 0] Set Master/Slave type
0
0 = Solo operator, 1 = Slave unit, 2 = Master unit
I5
[Ch 0] Set AC Charger or Solar
0
0 = DC + AC charger, 1 = DC + Solar charger
I6
[Fo 0] Enable Fire Dept. Open
0
0 = input disabled, 1 = enabled
I7
[oC 0] Enable Emergency close
0
0 = input disabled, 1 = enabled
I8
[SE 2] Inherent Sensor sens.
3
1 = Maximum sensitivity, 9 = Lowest sensitivity
I9
[SS 0] Inherent Sensor function
0
0 = normal (see
) 1 = Stop only - Usage Class 4 only
I10
[LC 0] Leaf delay Close
0
0 = none (1-7) ½ second steps (Master/Slave only)
I11
[Lo 0] Leaf delay Open
0
0 = none (1-7) ½ second steps (Master/Slave only)
I12
[rt 0] Maximum run timer
0
0 = 60 Seconds max run, 1 = 300 Seconds max run
I13
[EC 0] PEC reverse to open
0
0 = Close eye stops only, 1 = 2 sec reverse to open
I14
[EO 0] PEO reverse to close
0
0 = Open eye stops only, 1 = 2 sec reverse to close
I15
[gr 0] Edge reverse to open
0
0 = Edge reverses fully open, 1 = Edge reverses for 2 sec
I16
[Sr 1] IES reverse to open
1
0 = IES reverses fully open, 1 = IES reverses for 2 sec
I17
[PC 0] Set PEO/ PEC
– NO/NC
0
0 = Normally Open PE output, 1 = N.C. (Supervised)
I18
[gC 0] Set Edge input
– NO/NC
0
0 = Normally Open Edge output, 1 = Normally Closed
I19
[tC 1] Time clock/ Interlock input
1
0 = select Time Clock, 1 = select Open Interlock
I20
[dt 0] Disable Free Exit/Close Tmr
0
0 = disable Free Exit, 1 = disable Close Timer
I21
[or 1] OOLD detector function
1
0 = pause closing only, 1 = enable reversing to open
I22
[ir 1] IOLD detector function
1
0 = pause closing only, 1 = enable reversing to open
I23
[hd 1] SLD Shadow detector funct
1
0 = Hold open only, 1 = Hold closed + Hold open
I24
[dL 1] Vehicle detector logic
1
1 = Std, 2 = Close timer counts down even with loops active
I25
[r1 0] User relay 1 option
1
0 = disabled, 1
– 24 = see relay output options
I26
[r2 0] User relay 2 option
6
0 = disabled, 1
– 24 = see relay output options
I27
[r3 0] User relay 3 option
1
0 = disabled, 1
– 24 = see relay output options
I28
[tL 0] Gate Open alert
2
0 = 0 sec, 1= 15s, 2= 45s, 3= 75s, 4= 105s, 5= 135s
I29
[Lt 0] Loitering alert
3
0 = 0 sec, 1= 15s, 2= 45s, 3= 75s, 4= 105s, 5= 135s
I30
[SA 0] System Address
0
0 = no network, 1-
99 = network ―drop‖ address
I31
[ELd0] Test factory ELD*
0
0=Run, 1=show freq, 2=show call level 0-7, 3=set freq 1-4
I32
[iLd0] Test factory IOLD*
0
0=Run, 1=show freq, 2=show call level 0-7, 3=set freq 1-4
I33
[oLd0] Test factory OOLD*
0
0=Run, 1=show freq, 2=show call level 0-7, 3=set freq 1-4
I34
[SLd0] Test factory SLD*
0
0=Run, 1=show freq, 2=show call level 0-7, 3=set freq 1-4
*Refer to Detector & Loop Diagnostics more information.
These Notes Refer to the Menu Above:
I1
This setting must be configured or the gate cannot function and menu will not exit.
I4
This setting appear only if the factory has provided a DC powered gate operator
I8
IES stop only setting [SS __] does not appear unless set as a class 4 operator
I9-10
These settings appear only if the Installer Menu is set for Master / Slave function
I26-27
These settings appear only if the Installer Menu has set relays r1-r3 for these alerts