HySecurity Hy-5A Vehicle Detector Installation


1. Insert the locking end of each of

two 1‖ long white plastic standoffs into the mounting holes on the

detector.

2. Plug the detector into the appropriate socket along the right side edge of the Smart Touch

Controller board for the detector function that is desired. Be careful to align the six detector pins
into the socket correctly, and then snap the standoffs into the holes on the right side of our control
enclosure.

3. Route the loop wires through the wire clips provided, and connect the loop leads to the two

terminals directly on the detector. Tighten the terminal screws securely.

4. When the power is turned on, the detectors will immediately tune themselves.

5. Once enabled, if the detector module is unplugged, a communications alert [AL10] will be

triggered, then if the fault continues, [Err3]

―detector failed‖ is displayed. The operator will also

run as if the affected detector is triggered. The [Err3] can only be cleared by pressing the Reset
button, which electronically uninstalls the detector. See Detector & Loop Diagnostics.

6. The Smart Touch Controller automatically governs frequency selection of all Hy-5A detector

modules. This simplifies installation and guarantees that there is no cross talk between multiple
loops. The frequency can also be manually selected if needed, see the installer menu options.

7. Sensitivity is the only adjustment on the detector itself. Generally sensitivity does not need to be

increased unless the loop is large loop or there are multiple loops connected to one detector. Do
not exceed more than 200 sq/ft of loop area to one detector.

The rotary switch for sensitivity has eight settings, which are as follows:
0 = Low, 1 = Normal, 2 = Medium, 3 = High (0-3 with the boost feature*)
4 = Low, 5 = Normal, 6 = Medium, 7 = High (4-7 no boost feature*)

*Boost increases the sensitivity during a call and is very useful for maintaining continuous
detection when the signal may become weak, such as semi-trucks.

8. Vehicle detector functions are configurable in the Installer Menu as shown below.

Installer Menu Options Default

Description

I19

[or 1] OOLD detector function

1

0 = pause closing only, 1 = enable reversing to open

I20

[ir 1] IOLD detector function

1

0 = pause closing only, 1 = enable reversing to open

I21

[hd 1] SLD- shadow detector function

1

0 = Hold open only, 1 = Hold closed + Hold open

I22

[dL 1] Vehicle detector logic

1

1 = std, 2 = Close timer counts even with loops active

The outside and inside Obstruction Loop Detectors ―OOLD‖ or ―IOLD‖ are factory configured to fully re-
open the gate as a default setting. In the Installer menu, each detector can individually be set so that
when the gate is closing there is only a pause if triggered. To change the IOLD setting, go to the menu
item [ir__] and set to 0. For the OOLD, go to the menu item [or__] and set to 0.