Instructions regarding intended installation – Controlled Products Systems Group 6300-080 User Manual
Page 8
Instructions regarding intended installation:
• Install the gate operator only if:
1.
The operator is appropriate for the construction of the gate and the usage class of
the gate.
2.
All openings of a horizontal slide gate are guarded or screened from the bottom of
the gate to a minimum of 4 feet (1.22 m) above the ground to prevent a 2 ¼ inch
(57.2 mm) diameter sphere from passing through the openings anywhere in the gate,
and in that portion of the adjacent fence that the gate covers in the open position.
3.
All exposed pinch points are eliminated or guarded.
4.
Guarding is supplied for exposed rollers.
• The operator is intended for installation only on gates used for vehicles. Pedestrians must be
supplied with a separate access opening. The pedestrian access opening shall be designed
to promote pedestrian usage. Locate the gate such that persons will not come in contact with
the vehicular gate during the entire path of travel of the vehicular gate.
• The gate must be installed in a location so that enough clearance is supplied between the
gate and adjacent structures when opening and closing to reduce the risk of entrapment.
Swinging gates should not open into public access areas.
• The gate must be properly installed and work freely in both directions prior to the installation
of the gate operator. Do not over-tighten the operator clutch, pressure relief valve or reduce
reversing sensitivity to compensate for a damaged gate.
• For gate operators utilizing Type D protection:
1.
The gate operator controls must be placed so that the user has full view of the gate
area when the gate is moving.
2.
A warning placard shall be placed adjacent to the controls.
3.
An automatic closing device (such as a timer, loop sensor, or similar device) shall not
be employed.
4.
No other activation device shall be connected.
• Controls intended for user activation must be located at least ten feet (10’) away from any
moving part of the gate and where the user is prevented from reaching over, under, around or
through the gate to operate the controls. Outdoor or easily accessible controls should have a
security feature to prevent unauthorized use.
• The Stop and/or Reset button must be located in the line-of-sight of the gate. Activation of
the reset control shall not cause the operator to start.
• A minimum of two (2) WARNING SIGNS shall be installed, one on each side of the gate
where easily visible.
• For gate operators utilizing a non-contact sensor:
1.
See the instructions on the placement of non-contact sensors for each type of
application.
2.
Care shall be exercised to reduce the risk of nuisance tripping, such as when a
vehicle trips the sensor while the gate is still moving in the opening direction.
3.
One or more non-contact sensors shall be located where the risk of entrapment or
obstruction exist, such as the perimeter reachable by a moving gate or barrier.
Page
8
6300-065-E-4-08