3.2 Switch

Settings

The two DIP-switches located on the circuit board are used to program the operator to operate in
various modes and to turn on or off various operating features. Whenever a switch setting is
changed, power to the operator must be turned OFF and then turned back on for the new setting to
take affect. Check and review ALL switch settings prior to applying power to the operator.

SW 1 (TOP SWITCH)

SWITCH FUNCTION SETTING

DESCRIPTION

1 and 2

Relay

1-OFF 2-OFF
1-OFF 2-ON
1-ON 2-OFF
1-ON 2-ON

Relay activated only when gate is FULL OPEN.
Relay activated whenever gate is NOT CLOSED.
Relay activated when gate is OPENING and OPEN.
Relay activated when gate is OPENING and CLOSING.

3 Open

Loop

Logic Output

OFF
ON

Output of loop detector in OPEN port is switched to terminal 12.
Output of loop detector in OPEN port feeds directly to processor.

4 Auto-Close

Timer

OFF
ON

Auto-close timer is OFF. Manual input required to close gate.
Auto=close timer is ON. Adjustable from 1-23 seconds.

5 Slide

Gate

Swing Gate

OFF
ON

Switch is in the OFF position for slide gate operators.
Switch is in the ON position for swing gate operators.

6 Single

Button

Control

OFF
ON

Switch must be OFF when 3-button control is used.
Switch must be ON when single button control is in use.

7 Bi-parting

Gates

Single Gate

OFF

ON

Switch is OFF when bi-parting (primary/secondary) gates are
used.
Switch is ON for single gate operation.

8 Tamper

Protect

OFF
ON

Tamper protect is turned OFF.
Tamper protect is turned ON.

SW 2 (BOTTOM SWITCH)

SWITCH FUNCTION SETTING

DESCRIPTION

1 Direction

Primary

OFF
ON

Changes direction of PRIMARY operator. Set so that the operator
runs in the OPEN direction upon initial activation after power-up.

2 Direction

Secondary

OFF
ON

Changes direction of SECONDARY operator. Set so that the
operator runs in the OPEN direction upon initial activation after
power-up.

3 Self

Test

OFF
ON

Normal operation.
Self test. Operator must be disconnected from gate to run test.

4 Motor

Control

OFF

ON

Switch is OFF when both primary and secondary operator motors
are powered from main terminals 4 and 5. Applies to operators
originally manufactured with 4501, Rev O boards or lower).

Switch is ON when secondary operator motor is powered from the
secondary motor terminals. Applies to operators manufactured
with 4501, Rev P boards and higher, and all 4502 boards.

5 Shadow

Input

OFF
ON

Terminal 15 is a standard REVERSE input with this switch OFF.
Terminal 15 is a SHADOW input with this switch ON.

6 Gate

Overlap

OFF
ON

Primary and secondary operators start at the same time.
Secondary operator starts 1-2 seconds prior to the primary
operator.

7

Not Used

OFF

Leave in OFF position.

8

Not Used

OFF

Leave in OFF position.

Page

36