beautypg.com

Controlled Products Systems Group 6300-080 User Manual

Page 17

background image

Height determined by
installation requirements

Determined by soil
conditions and local code

22

12

• The height requirement is

determined by adjusting the
mounting plate/post assembly so
that the top of the mounting plate
is 5 inches above the top of the
gate rail (Figure 4). This will allow
you to mount the gate bracket
onto the bottom rail of the gate
and will keep the crank and
connecting arms level (see page
22, Figure 10).

• The top of the mounting plate

must be at least six (6) inches
above the ground. If it is less than
this, the gate arms will scrape the
ground when the operator starts.

Figure 3

• It is very important that the operator mounting plate is level.

10

12

Gate Hinge

Ga

te

Fra

m

e

Determined by
soil conditions
and local code.

5

Ground Level

Height determined by

installation requirements to

align arms with gate frame.

Minimum 7".

Gate Bracket

Figure 4