Swing Gate Requirements
The gate must be installed in a location so that
enough clearance is supplied between the gate and
adjacent structures when opening and closing to
reduce the risk of entrapment. Swinging gates shall
not open into public access areas.
UL 325 56.8.4.c
If space is greater than 4" or less than 16", entrapment protection in this area is required.
ASTM F2200 7.1.1.1 and 7.1.1.2
The operator is intended for installation only on gates used for vehicles.
Pedestrians must be supplied with a seperate access opening. The
pedestrian access opening shall be designed to promote pedestrian
usage. Locate the gate such that persons will not come in contact with
the vehicular gate during the entire path of travel of the vehicular gate.
(ref. UL325 56.8.4.b)
Fence
Gate
A
Gate
Pilaster
A
Pedestrian
Access
Fence
Gate
Pilaster
A
B
B
With the hinge mounted on the corner of the pilaster, the entrapment area is eliminated and
protection is not required for this area.
C
C
Not Allowed
OK
Gates shall have smooth bottom edges, with vertical bottom edged protrusions not exceeding 0.50 in.
ASTM F2200 4.3