4 auxiliary device wiring – Controlled Products Systems Group 6300-080 User Manual
Page 31
2.4 Auxiliary
Device
Wiring
DOORKING, INC., INGLEWOOD, CA 90301
Title:
Date:
Rev.
Dwg. No.
Green
Red
White
2351-010
Circuit Board
DoorKing 1404-080
Remote Reset Switch
DoorKing 2351-010
Tracker Expansion Board
1
2
The auxiliary stop switch will stop a moving gate when activated or will prevent the gate operator from starting when activat ed. Note that
this input is normally open and that a switch closure is required to activate the stop function . Because of this, the auxiliary stop
shown must NEVER be used as a safety interlock device .
Jumper is placed across terminals 13 and 14 ONLY WHEN THE AUXILIARY STOP INPUT IS USED.
The Remote Alarm Reset Station MUST be mounted in the line -of-sight of the gate operator.
Using a 2351-010 Tracker Expansion Board, operator data can be sent to the access controller (DoorKing 1833, 1835, 1837 or 1838 only).
Refer to Installation Manual 2351-065 for detailed information.
2
3
4
3
4
9/07
A
4502-AUXDEV-1
Model 6050, 6100 and 6300
Auxiliary Device Wiring Diagram
4502-010
Circuit Board
Auxiliary Terminals
12
3
4
56
78
9
1
0
1
1
1
2
1
3
1
4
15
16
1
7
18
19
20
1
2
3
4
5
6
7 8
Auxiliary Stop Using Magnetic Switch
1
N.
O.
N.
C
.
COM
N.
O.
N.
C
.
COM
Normal
Operation
Operator
Stopped
6300-065-E-4-08
Page
31