3 loop detector wiring, Page – Controlled Products Systems Group 6300-080 User Manual
Page 30
![background image](/manuals/334936/30/background.png)
2.3 Loop Detector Wiring
Detail A
TB 1
From inside
Reverse loop
From outside
Reverse loop
DOORKING, INC., INGLEWOOD, CA 90301
Title:
Date:
Rev.
Dwg. No.
Loops and loop detectors MUST be installed with this gate
operator to help prevent the gate from accidentally closing on
vehicular traffic.
Loop detector wiring is shown for DoorKing plug -in loop
detectors only. If other loop detectors are used, refer to the
installation instructions supplied with those detectors for wiring
instructions.
If other detectors are used, use a separate power supply to
power these detectors.
Loop layout shown is for a typical swing gate application with
two-way traffic, or one-way exit only traffic.
Reverse loops are wired in series. See detail A.
Refer to the Loop Information Manual (available from
www.dkaccess.com) for more information on loops and loop
detectors.
9/07
A
4502-LOOP-1
Model 6050, 6100 and 6300
Loop Detector Wiring
Exit
Loop
1
2 3
4 5
6 7
8
ON
1
2 3
4
5
6 7
8
SW1
SW2
Re
la
y Co
n
ta
c
t
Timer
Power
Reverse
Loop
Shadow
Reverse
Exit
Reverse
DKS 9410
15
1
6
17
18
19
20
Detail A
DKS 9409
COM
N.O.
Page
30
6300-065-E-4-08