2.5 Primary / Secondary (Dual) Gate Wiring
DOORKING, INC., INGLEWOOD, CA 90301
Title:
Date:
Rev.
Dwg. No.
Red
Brown
Orange
2
3
4
5
6
9/07
A
4502-DUAL-1
Model 6050, 6100 and 6300
Primary / Secondary Wiring Diagram
Secondary
Operator
1
2
3
4
5
6
7
8
9
1
0
1
11
21
31
4
15
16
1
7
1
8
19
20
1
Connect the Primary / Secondary interconnection wiring as shown. Wire colors are based
on DoorKing interconnection cable (P/N 2600-75x).
Place a jumper from terminal 15 to terminal 16 in the PRIMARY operator.
Plug a two-channel (P/N 9409-010) loop detector into the REVERSE loop port in the
PRIMARY operator. Connect loops and loop detector as shown.
2
3
4
5
6
Connect chassis ground to chassis ground.
Do
o
rK
in
g
94
1
0
-010
TB
1
Yellow
Blue
White
Conduit
Reverse
Reverse
Exit
Shadow
4502-010
Circuit Board
Primary
Operator
Auxiliary Terminals
1
2
3
4
5
6
7
8
9
10
1
1
12
13
14
15
16
1
7
18
19
20
1
2
3
4
5
6
7
8
Secondary
Motor
Re
d
White
Brown
Orange
Bl
u
e
Yellow
Do
o
rK
in
g
940
9
-0
10
TB
1
TB
2
TB
3
A
A
B
1
Place a jumper from terminal 19 to terminal 20 in the SECONDARY operator.
Plug a single channel (P/N 9410-010) loop detector into the EXIT loop port in the
PRIMARY operator. Connect loop and loop detector as shown.
A
Open direction non-contact sensor.
B
Close direction non-contact sensor.
Page
32