3.2.1 SW 1 (Top Switch) Description and Function

Switches 1-2

: These work in conjunction with each other and determine when the relay on the board

will be activated. This relay can be used as a switch for various functions such as illuminating a
warning light when the gate is moving, or turning on a green light when the gate is full open. This
relay is not available for these uses if it is being used for the shadow loop function.

Switch 3

: Determines if the output of the loop detector (DoorKing loop detectors only) plugged into

the EXIT port will be sent directly to the microprocessor to open the gate, or if the output is directed to
terminal 12 where it can then be connected to other input terminals.

Switch 4

: Turns the auto close timer on or off. Maximum time that the close timer can be set for is

approximately 23 seconds.

Switch 5

: This switch enables the 4502 circuit board to be used in either a swing gate or slide gate

application. Some older DoorKing slide gate operators did use the 4501 circuit board for control.
This switch is here to allow use of this board on these older products.

Switch 6

: Sets up the circuit board for single button or 3-button (open-close-stop) logic (DoorKing 3-

button control stations only). Keep this switch in the ON position for single button control.

Switch 7

: Sets up the circuit board for single or primary / secondary (dual) gate operation.

Switch 8

: If the gate is forced open, the tamper-protect system will start the motor in the close

direction when the operator senses the forced open condition.

3.2.2 SW 2 (Bottom Switch) Description and Function

Switch 1

: Sets direction of the primary operator so that the operator cycles open upon initial power

up and open command. If the operator begins to cycle close upon initial power up and open
command, turn power off and change the setting on this switch.

Switch 2

: Sets direction of the secondary operator so that the operator cycles open upon initial

power up and open command. If the operator begins to cycle close upon initial power up and open
command, turn power off and change the setting on this switch.

Switch 3

: This switch is a self-test feature that checks various functions of the circuit board and is

used for bench test only. Do not run this test with the operator connected to the gate.

Switch 4

: This switch applies high voltage motor power to the two secondary operator motor

terminals located at the top of the board. If a primary / secondary system is in use, this switch should
be ON and the secondary motor wires connected to the secondary operator motor terminals. For
single gate applications, this switch can be turned OFF.

Switch 5

: This switch sets the input at terminal 15 to act as a normal reverse input or to act as a

shadow input. A shadow input will only hold the gate operator in the open position once it is in the full
open position. A shadow input will not reverse the direction of the gate operator once it begins
its close cycle.

Switch 6

: Used in primary / secondary applications, turning this switch ON will cause the start of the

primary operator to be delayed 1-2 seconds. This allows the secondary gate to reach the full closed
position prior to the primary gate, which is desirable when the gates are constructed with an overlap
or if a magnetic lock is used to secure the gates.

Switches 7-8

: Spare switches. Leave these in the OFF position.