2.7 Auxiliary Terminal Description

The auxiliary terminal is located on the 4502 circuit board just to the right of main terminals 18 and
19. Auxiliary terminals are numbered 1 through 8.

1. ALARM

OUTPUT

Provides power to activate the entrapment alarm.

2.

ALARM RESET INPUT

Input to reset the operator after an entrapment alarm.

3. COMMON

Common for alarm output and alarm reset input.

4. TRACKER

DATA

Supplies gate operator data to Tracker expansion board (P/N 2351-010). Refer to
the Tracker Installation and Wiring Manual for detailed information.

5. TRACKER

DATA

Supplies gate operator data to Tracker expansion board (P/N 2351-010). Refer to
the Tracker Installation and Wiring Manual for detailed information.

6. TRACKER

DATA

Supplies gate operator data to Tracker expansion board (P/N 2351-010). Refer to
the Tracker Installation and Wiring Manual for detailed information.

7. PHOTO-BEAM

INPUT

This input will cause the gate operator to stop when activated in either the opening or
closing cycles. The gate operator will remain stopped until the photo-beam input is
cleared, at which time the operator will resume normal operation.

8. COMMON

Common for photo-beam input.