SECTION 3 – ADJUSTMENTS
The switch settings and adjustments in this chapter should be made after your installation and wiring
to the operator(s) is complete. Whenever any of the programming switches on the circuit board
are changed, power must be shut-off, and then turned back on for the new setting to take
effect.
3.1 Circuit Board Adjustments
• Set the DIP-switches on the circuit board to the desired setting. See switch-setting charts in
section 3.2.
• Auto close timer (when turned on) can be set from 1 second (full counter clockwise) to
approximately 23 seconds (full clockwise).
• Dry relay contacts (terminals 16-17) can be set for Normally Open (NO) or Normally Closed
(NC) operation by placing the relay shorting bar on the NO or NC pins respectively.
• Power LED indicates that low voltage power is applied to the circuit board. Input LEDs
should be OFF and will only illuminate when an input is activated. The pulse LEDs will blink
as the operator is running. They can be either ON or OFF when the operator is stopped.
Tracker LEDs will flash as operator data is sent to the access controller (DoorKing models
1833, 1835, 1837 or 1838 only).