15

Installation

3. installation of the pneumatic control unit

Supports

Pilot air

ports

Fastening

screws

max. 0,5 Nm

Fig. 8: Installation of the Pneumatic Control Unit, 21xx series

Align the Pneumatic Control Unit until the supports of the Pneumatic
Control Unit can be inserted into the pilot air ports of the actuator
(see also “Fig. 8”).

Push the Pneumatic Control Unit, without turning it, onto the
actuator until no gap is visible on the form seal.

note!

too high torque when screwing in the fastening screw does
not ensure degree of protection ip65 / ip67.

▶ The fastening screws may be tightened to a maximum torque of

0.5 Nm only.

Attach the Pneumatic Control Unit to the actuator using the two
side fastening screws. In doing so, tighten the screws only hand-
tight (maximum torque: 0.5 Nm).

7.3.

installation on process valves of
series 20xx

procedure:

1. install switch spindle

Transparent cap

Position indicator

Actuator

Fig. 9: Installation of the switch spindle (1), series 20xx

Unscrew the transparent cap on the actuator.

Using a hexagon socket key, unscrew the orange/yellow position
indicator from the inside of the actuator.

Press the O-ring downwards into the cover of the actuator (see
“Fig. 10”).

Manually screw the switch spindle (and the plugged-on guide
element) together with the plastic part onto the spindle of the
actuator, but do not tighten spindle yet.

english

Type 8697