12 malfunctions, 13 spare parts – Burkert Type 2037 User Manual
Page 33

33
Malfunctions
12
malfuncTiOns
malfunction
cause / remedial action
Actuator
does not
switch
Control connection interchanged *
CFA
→
Connect lower control connection
CFB
→
Connect upper control connection
CFI
→
Upper control connection: Close
Lower control connection: Open
* see “Fig. 32: Control air connection”
Control pressure too low
→
See pressure specifications on the type label.
Medium pressure too high
→
See pressure specifications on the type label.
Valve is not
sealed
Medium pressure too high
→
See pressure specifications on the type label.
Control pressure too low
→
See pressure specifications on the type label.
Flow rate
reduced
PTFE diaphragm bulging
→
Replace diaphragm.
13
spare parTs
Warning!
risk of injury when opening the actuator body!
The actuator contains a tensioned spring. If the body is opened,
there is a risk of injury from the spring jumping out!
▶ Carefully open the actuator body and hold it in such a way that any
parts which jump out cannot injure anyone or damage anything.
CauTion!
risk of injury and/or damage by the use of incorrect parts!
Incorrect accessories and unsuitable spare parts may cause injuries
and damage the device and the surrounding area.
▶ Use only original accessories and original spare parts from
Bürkert.
Types 2030, 2031, 2031 K, 2032 and 2033 are available as spare
parts for the piston-controlled diaphragm valves.
• Seal set,
• Diaphragm.
english
Type 2030, 2031, 2031 K, 2032,
2033, 2037