Burkert Type 2037 User Manual
Page 10
10
TechnicalData
maximum permitted medium pressure for control function a
The values apply to body made of:
• Plastic,
• VA forged steel and VA precision casting, VA block material as well
as VA tube-formed body with socket, DIN welding neck flange and
welded connection in accordance with EN ISO 1127 (ISO 4200)
connection
size
dn
[mm]
actuator
size ø
[mm]
max. sealed medium pressure [bar]
pressure on one
side
pressure on both
sides
epdm / fkm ptfe epdm / fkm ptfe
4/6/8/10
40
10
10
10
9
15
50
8.5
5
7
3.5
63
10
10
10
9
20
63
10
5
8
5
80
10
10
10
10
25
63
3
-
2
-
80
10
7.5
8.5
5.5
32
100
10
8
9
6
40
100
6.5
6
5
5
125
10
10
10
9
50
100
4.5
2.5
3.5
2
125
8
7
7
6
65
125
7
4
4.5
2
Tab. 4: Maximum permitted medium pressure CFA
maximum permitted medium pressure for control function a
The values are valid for:
• VA tube-formed body with welded nozzles in accordance with
DIN 11850 series 2, with OD weld-on ends, with ANSI and
JIS welding neck flange
connection
size
dn
[mm]
actuator
size ø
[mm]
max. sealed medium pressure [bar]
pressure on one
side
pressure on both
sides
epdm / fkm ptfe epdm / fkm ptfe
10
40
10
10
10
9
15
50
9
9
7
7
63
10
10
10
10
20
50
9
9
7
7
63
10
10
10
10
25
63
10
8
7
5
80
10
10
10
9
32
63
3
-
2
-
32
80
10
8
7.5
6
40
100
10
8
8
6
50
100
8
8
6.5
6.5
125
10
10
10
8.5
65
125
7
4
4.5
2
Tab. 5: Maximum permitted medium pressure CFA
english
Type 2030, 2031, 2031 K, 2032,
2033, 2037