beautypg.com

Programmer’s reference manual printer settings – Datamax-O'Neil Labelpoint Programmer’s Manual User Manual

Page 50

background image

PROGRAMMER’S REFERENCE MANUAL

Printer settings

Page 46

44

Alternate end-of-line (EOL) character. This parameter must be set before CR
as end-of-line can be disabled. See parameter 45. Valid values for n are all
decimal ASCII values.

45

6

Disable CR as end-of-line. Only valid when an alternate end-of-line
characters is enabled. See parameter 44. Valid values for n are {0,1} and they
are interpreted as follows:

0 = CR enabled (default)
1 = CR disabled

46

4

Paper strobe time, in µs. The amount of blackness from a given strobe time
depends on paper type used. For most applications, however, the
recommended value is 510µs for Compact models and 350µs for Nova
models.

50

Silent mode. When transferring graphic files this parameter can be used to
disable ACK/NAK responses from the printer. Valid values are {0,1} and they
are interpreted as follows:

0 = printer will respond using ack/nak during file transfers
1 = printer will not respond during file transfers (default).

55

3

Get type of applicator.

0 = None
3 = Blow/Wipe/TampLong

62

3

Printer production year, two digits.

63

3

Printer serial number.

66

Enable application. When Application Center is used, this parameter must be
set for the application to start. Valid values for n are {0, 1} where 0 is disable
and 1 enable. Default is disabled. See the Application Center manual for
more information.

67

Printkey mode. This parameter is used to disable or change the functionality
of the printkey. Normally, a copy of last printout is made. This can be
disabled to make sure that no copy can be made of a unique printout, i.e a
ticket of some kind. It is also possible to trig a new printout, which
corresponds to sending the command ‘!P’. This can also be accomplished
when using a LTS. See parameter 93 for more information. Valid values for n
are {0, 1, 2} and they are interpreted as follows:

0 = copy of last printout (default)
1 = printkey disabled
2 = dormant (or trigged) print

68

Horizontal print position adjustment, in

1

/

10

mm. Shifts the print picture east

(positive values) or west (negative values). Valid values for n are all integer
values. Default is 0.

6

RAM parameter. Not stored in non-volatile memory.

This manual is related to the following products: