PROGRAMMER’S REFERENCE MANUAL

Printer settings

Page 42

Printer settings

The printer settings can be set on command from the host computer. The initial settings

used at power-up are stored in non-volatile memory. Some settings can be changed during

operation while others always retain their power-up value. Using the commands described

below can access all of the parameters, but most of the common settings are available via the

configuration menu, accessible through the COM ports, Telnet port or the built-in webserver in

the printer. See section ‘configuration menu’ below.

Get current value:

!X

The printer responds with the current value of the parameter , followed by a carriage

return character.

Set value:

!Y

The parameter is set to , which must be a decimal number. Not all parameters can

be set, see the table below.

Make changes permanent: !Z

The current settings are written into the non-volatile memory so that they will still be in

effect when the printer has been switched off.

Note! All parameters that do not have the

5

suffix must be made permanent with the !Z

command. The printer must then be switched off and back on (or restarted by
command) before the change becomes active.