Chapter 4 – Menu System

45

DISPLAYED ITEM

ITEM DESCRIPTION

COLUMN EMULATION

Allows the column dots per inch to be adjusted (153 - 253 dots), so that numbers smaller than the

printhead resolution reduce the printed output from right to left, where:

XXX Dots

Default setting is dependant on printer model.

ROW EMULATION

Allows the row dots per inch to be adjusted (103 - 303), so that numbers smaller than the printhead

resolution enlarge the height of the printed output and numbers larger reduce it, where:

XXX Dots

Default setting is dependant on printer model.

SOP EMULATION

Allows label positioning commands to function with backward compatibility when printing label

formats designed for legacy models, where:

DISABLED

Produces the natural start of print position. (Default Setting)

110 (PRODPLUS)

Emulates the Prodigy Plus® start of print position.

220 (ALLEGRO)

Emulates the Allegro® start of print position.

250 (PRODIGY)

Emulates the Prodigy™ start of print position.

BACK AFTER PRINT

Determines media movement when a cutter, present sensor, peel and present, or GPIO is enabled,

where:

MODE

Repositions media, where:

DISABLED

Movement occurs only when the next label is ready to print, minimizing edge curling.

(Default

Setting)

ENABLED

Movement occurs according to BACKUP DELAY timing after a cut, cleared sensor, or SOP to allow

fastest throughput.

BACKUP DELAY

(1/50s)

Instructs the printer to retract a presented label after a specified time elapses (0 – 255, in one-

fiftieth of a second increments), where:

000

Retraction occurs when the next label is received and processed. (Default Setting)

FONT EMULATION

Allows font substitution for all internal fonts where:

STANDARD FONTS

Prints using a standard (internal) font. (Default Setting)

CG TIMES

Prints using the CG Times font.

USER ID S50

Prints using a downloaded font.

LABEL STORE

Determines the command recall level used when retrieving stored label formats, where:

STATE & FIELDS

Recalls the printer state (i.e., heat, speed settings, etc.) and the label-formatting commands for the

stored label. (Default Setting)

FIELDS ONLY

Recalls the label-formatting commands for the stored label.

MENU LANGUAGE

Selects the menu and configuration label language. Only languages that are resident will be

displayed (see Appendix D), where:

ENGLISH

Enables English (Default Setting)

DISPLAY SETTINGS

Determines the appearance of the items in the display, where:

GRAPHIC DISPLAY

MODE

Determines the magnification of the displayed items, where:

STANDARD

Is the normal setting.

ENHANCED

Is the enlarged setting.

DISPLAY UNITS

Determines the displayed

type of distance information

, where:

STANDARD

Displays the information according to the UNITS OF MEASURE setting (see above).

IMPERIAL

Displays the information in inches.

METRIC

Displays the information in millimeters and centimeters.

DISPLAY BACKLIGHT

Controls the mode and “ON” time of the display’s backlight

BACKLIGHT MODE

Sets the mode in which the backlight is activated. Choices are Always On, Always Off, or Auto.

AUTO ON TIME

Set the amount of time the backlight will remain on. BACKLIGHT MODE (see above) must be set to auto.

DISPLAY CONTRAST

Adjusts the displays contrast (0-100), where:

50

Is the default setting

FAULT HANDLING

Determines the intervention required and the disposition of the label in process when a fault occurs,

where:

LEVEL

Selects the user action and the reprint status upon declaration of a fault, where:

NO REPRINT

Printing stops and a fault message is displayed. Following correction of the problem, the FEED Key

must be pressed to clear the fault, but the label in process is not reprinted.

STANDARD

Printing stops and a fault message is displayed. Following correction of the problem, the FEED Key

must be pressed to clear the fault then the label in process is reprinted. (Default Setting.)

BUZZER

Sets a scalable font boldfacing amount, where:

ENABLED

Enables the printers buzzer. (Default Setting)

DISABLED

Disables the printers buzzer.

SCL FONT BOLD FACTOR

Sets a scalable font boldfacing amount, where:

08 (1 – 36)

Is the setting, based on an incrementing scale, where eight (08) is nominal.