Chapter 3 – Printer Operation

Advanced Entry Calibration (continued)

Step

Action

Displayed Message

Comment

L

Using the

or

button, set the

Gain Number determined in the
previous step. Press the

button

to enable the setting.

OK

This example uses Gain Number

18.

M

Press the

button again to re-

enter the TRAN SENSOR GAIN (or

REFL SENSOR GAIN, if using

reflective media) menu item.

Complete a table (see example

below) using new measurements,

as follows:

(A) Raise the Cover Assembly.

Place the label over the Media

Sensor then lower and latch the

Cover Assembly. Record the

sensor reading as “Paper”.

(B) Raise the Cover Assembly.

Place the liner, notch, or mark

over the Media Sensor then lower

and latch the Cover Assembly.

Record the sensor reading as “Gap

(or Mark)”.

(C) Raise the Cover Assembly.

Remove all media from the Media

Sensor then lower and latch the

Cover Assembly. Record the

sensor reading as “Empty”.

TRAN SENSOR GAIN

yyy

18

(0 - 31)

Where “yyy” is a numerical value

representing the current sensor

reading.

The re-sampled values may

differ from those previously

noted. This is normal; do not

readjust the Media Sensor.


Selected Gain Table

Gain Number

Paper

Gap (or Mark)

Empty

18 174 42 9