32 chapter 3 – printer operation – Datamax-O'Neil E-Class Mark III Operator’s Manual User Manual
Page 38
32
Chapter 3 – Printer Operation
Advanced Entry Calibration (continued)
Step
Action
Displayed Message
Comment
L
Using the
or
button, set the
Gain Number determined in the
previous step. Press the
button
to enable the setting.
OK
This example uses Gain Number
18.
M
Press the
button again to re-
enter the TRAN SENSOR GAIN (or
REFL SENSOR GAIN, if using
reflective media) menu item.
Complete a table (see example
below) using new measurements,
as follows:
(A) Raise the Cover Assembly.
Place the label over the Media
Sensor then lower and latch the
Cover Assembly. Record the
sensor reading as “Paper”.
(B) Raise the Cover Assembly.
Place the liner, notch, or mark
over the Media Sensor then lower
and latch the Cover Assembly.
Record the sensor reading as “Gap
(or Mark)”.
(C) Raise the Cover Assembly.
Remove all media from the Media
Sensor then lower and latch the
Cover Assembly. Record the
sensor reading as “Empty”.
TRAN SENSOR GAIN
yyy
18
(0 - 31)
Where “yyy” is a numerical value
representing the current sensor
reading.
The re-sampled values may
differ from those previously
noted. This is normal; do not
readjust the Media Sensor.
Selected Gain Table
Gain Number
Paper
Gap (or Mark)
Empty
18 174 42 9