Operating mode, Polled mode, Device net user manual – BEI Sensors MHK5 Absolute Hollow Shaft Encoder User Manual
Page 8

DEVICE NET USER MANUAL
BEI IDEACOD SAS
Espace Européen de l’Entreprise
9, rue de Copenhague
B.P. 70044 Schiltigheim
F 67013 Strasbourg Cedex
Tél
: +33 (0)3 88 20 80 80
Fax : +33 (0)3 88 20 87 87
Mail :
Web : www.bei-ideacod.com
4. Operating Mode
4.1. Polled Mode
For switching the polled mode on the following
telegrams are needed. Further it is assumed in
the
following example a master MAC ID of 0A hex
and a slave MAC ID of 03 hex.
Allocate Master / Slave Connection Set
1. Allocate Polling
Byte Offset Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0
Frag [0] XID
MAC ID
1
R/R [0] Service [4B]
Class ID [03]
Instance ID [01]
Allocation Choice [03]
0
0
Allocator MAC ID
Example:
CAN-ID
Byte 0
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
41E
0A
4B
03
01
03
0A
1. Setting the Expected_packet_rate of the Explicit Message Connection on 0:
Example:
CAN-ID
Byte 0
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
41C
0A
10
05
01
09
00
00
1. Setting the Expected_packet_rate of the Polling Connection on 0:n:
Example:
CAN-ID
Byte 0
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
41C
0A
10
05
02
09
00
00
Page 8
UME-OCD-D2
Version 05/04