Optional capabilities vectorstar™ ms4640b series – Atec Anritsu-MS4640B User Manual
Page 34

34
PN: 11410-00611 Rev. A
MS4640B Series TDS
Optional Capabilities
VectorStar™ MS4640B Series
DifferentialView™ — Option 043
Description
When combined with Option 031 Dual Source Architecture, provides dual source control and calibrations required
for stimulating and measuring differential devices. Allows true differential and common mode device drives.
Corrects mismatch introduced error of the DUT to VNA interface via real and time calibration. This mode supports
balanced in/out or combined balanced and single source drive configurations. In addition, it provides the ability
to control amplitude and phase offsets of the drive conditions as well as swept phase offset for custom
characterization.
Required Options
Option 031 Dual Source Architecture
Compatible Options
All
Incompatible Options
None
Multiport Systems
Requires an MN4690B Series Multiport System for full differential characterization of a multiport device.
Direct Access Loops — Option 051
Access Loops Per Port
Adds three (3) Access loops per port for Source, Test, and Receive Paths.
Note: Direct access loops are not available for VNAs equipped with Options 061 or 062, which include access
loops.
Front Panel Loops
≥ 2.5 GHz Frequency Coverage loops, located at front panel.
Rear Panel Loops
< 2.5 GHz Frequency Coverage loops, located at rear panel.
Active Measurements Suite – Options 061/062
Adds Step Attenuators, Bias Tees, Direct Access Loops, and Gain Compression and Efficiency Measurement Capabilities.
MS4642B and MS4644B Attenuators
70 dB, 10 dB/step
MS4645B and MS4647B Attenuators
60 dB, 10 dB/step
Option 061
Two (2) attenuators: One in Source 1 path, and one in Receive 2 path.
Option 062
Four (4) attenuators: One in each Source path and in each Receive path.
Bias Tees
0.5 A maximum, 40 VDC maximum
3 kHz BW (nominal), looking into a High Impedance 10 MΩ to Ground for DUT
Static Discharge Protection located at rear panel.
Access Loops
Includes Option 051 loops, listed above.
(Option 051, 061, and 062 are mutually exclusive)
Gain Compression
Swept Power Gain Compression at a CW frequency P
x dB
over Swept Frequency, up to 401 points.
70 kHz Low End Frequency Extension – Option 070
Extends the VNA standard 10 MHz low-end start frequency to 70 kHz, providing 70 kHz to 20, 40, 50, or 70 GHz coverage models. The low-end is
allowed to extend to 40 kHz.
MS4647B Broadband/Millimeter-Wave Connection Capability – Option 080/081
For a standalone MS4647B VNA instrument. Provides connection capability to the ME7838A Broadband/Millimeter-Wave system.
Option 080
Modular Broadband connection capability for MS4647B VNAs without Option 051, 061, or 062.
Option 081
Modular Broadband connection capability for MS4647B VNAs with Option 051, 061, or 062.
ME7838A Technical Data Sheet
For detailed ME7838A specifications, see the VectorStar ME7838A Modular Broadband/Millimeter-Wave Technical
Data Sheet – 11410-00593.
MS4640B Series Banded Millimeter-Wave Connection Capability – Option 082/083
For standalone MS4642B, MS4644B, and MS4645B VNA instruments. Provides connection capability to the ME7838A Millimeter-Wave system.
Option 082
Millimeter-Wave connection capability for MS4640B Series VNAs without Option 051, 061, or 062.
Option 083
Millimeter-Wave connection capability for MS4640B Series VNAs with Option 051, 061, or 062.
ME7838A Technical Data Sheet
For detailed ME7838A specifications, see the VectorStar ME7838A Modular Broadband/Millimeter-Wave Technical
Data Sheet – 11410-00593.
MS4640B Series Banded/Broadband/Millimeter-Wave Connection Capability – Option 084/085
For standalone MS4642B, MS4644B, MS4645B, and MS4647B VNA instruments. Provides connection capability to the ME7838A Millimeter-Wave
system when Option 031, Dual Source Architecture is installed.
Option 084
Millimeter-Wave connection capability for MS4640B Series VNAs without Option 051, 061, or 062.
Option 085
Millimeter-Wave connection capability for MS4640B Series VNAs with Option 051, 061, or 062.
ME7838A Technical Data Sheet
For detailed ME7838A specifications, see the VectorStar ME7838A Modular Broadband/Millimeter-Wave Technical
Data Sheet – 11410-00593.