PN: 11410-00611 Rev. A

MS4640B Series TDS

Optional Capabilities

VectorStar™ MS4640B Series

IF Digitizer — Option 035

Description

When combined with Option 042 PulseView™, adds the capability to generate and measure pulsed signals. Four

internal signal generators are included enabling singlet, doublet, triplet, quadruplet, and/or burst signal

generation. Pulse measurements include pulse profile, point-in-pulse, and pulse-to-pulse capability.

Required Options

None

Compatible Options

Option 002 Time Domain

Option 007 Receiver Offset

Option 031 Dual Source Architecture

Option 042 PulseView™

Option 051 Direct Access Loops

Options 061/062 Active Measurements Suite

Option 070 70 kHz Low Frequency Extension

Options 080/081 Broadband/Millimeter-Wave

Options 082/083 Banded Millimeter-Wave Extension

Options 084/085 Broadband/Banded/Millimeter-Wave Extension

Incompatible Options

None

Multiport Systems

Compatible with the MN4690B Series Multiport System on any model VNA; pulse capability is only available when

configured as a 2-Port VNA.

Fast CW (non-pulsed)

Captures up to 400 million data points per measurement channel with variable acquisition rates from 80 MHz to

400 MHz.

This capability enables long time records (0.5 s to 2.5 s, depending on acquisition rate) stored in files retrievable

via USB or a local area network.

Additional Information

For detailed pulse measurement theory, description, and operational information, see the VectorStar MS4640B

Series VNA Calibration and Measurement Guide, 10410-00318.

Typical plot of dynamic range with Option 035 activated.

Noise Figure – Option 041

Description

Adds the capability to measure degradation of the signal-to-noise ratio caused by components in a signal chain.

The Noise Figure measurement is based on a cold source technique for improved accuracy. Various levels of

match and fixture correction are available for additional enhancement.

Required Options

Option 051, Option 061, or Option 062

Compatible Options

Option 002 Time Domain

Option 007 Receiver Offset

Option 031 Dual Source Architecture

Option 035 IF Digitizer

Option 042 PulseView™

Option 070 70 kHz Low Frequency Extension

Option 081 Broadband/Millimeter-Wave

Option 083 Millimeter-Wave Extension

Options 085 Broadband/Banded/Millimeter-Wave Extension

Incompatible Options

Option 080 Broadband/Millimeter-Wave

Option 082 Banded Millimeter-Wave Extension

Options 084 Broadband/Banded/Millimeter-Wave Extension

Multiport System

MN4640B Series Multiport System on any model VNA; Noise Figure is only available when configured as a 2-Port

VNA.

Additional Information

For detailed Noise Figure measurement theory, description, and operational information, see the VectorStar