Reference

Information

This section contains the specifications for all models of the MLC and lists names and part
numbers of included parts and optional accessories for the product. Topics include:

Specifications

Part Numbers and Accessories

Specifications

MLC 62 Series Specifications

Control — host ports

Serial control port ........................... 1 bidirectional RS-232 on a 3.5 mm captive screw connector, 3 pole
Baud rate and protocol ................... 9600 baud, 8 data bits, 1 stop bit, no parity
Serial control pin configuration ....... Pin 1 = Tx, pin 2 = Rx, pin 3 = GND
USB control ports

Decora

®

models ....................... 1 front panel female mini USB B

MK and EU models .................. 1 side panel female mini USB B

USB standards ................................ USB 2.0, low speed
IR learning frequencies ................... 30 kHz to 60 kHz
IR learning distance ........................ 4" (10 cm) to 14" (36 cm) from the receiver (on front panel for Decora models,

side panel for MK and EU models)

Program control ............................. Extron configuration program for Windows

®

Extron Simple Instruction Set (SIS

)

Control — serial port (RS models)

Display control port ........................ (1) 3.5 mm captive screw connector, 2 pole for unidirectional RS-232 control

(±5 V)

Baud rate and protocol (RS-232) ..... 9600 (default), 19200, 38400, 57600, 115,200 baud; 8 (default) or 7 data bits;

1 stop bit; no parity (default), or even or odd parity

Control — IR port (IR models) or IR/serial port (RS models)

IR control port ................................ (1) 3.5 mm captive screw connector, 2 pole for IR or IR/Serial* (transmit only)

TTL level (0 to 5 V) modulated infrared control (all models) from 30 kHz up to
60 kHz, or ±5 V RS-232 control (RS models, transmit only)
*For RS models, IR/serial ports are configurable via software, serial
communication is the default.

Baud rate and protocol ................... For RS models:

9600 (default), 19200, 38400, 57600, 115,200 baud; 8 (default) or 7 data bits;
1 stop bit; no parity (default), or even or odd parity

Control — relay (RS models)

Number/type .................................. 2 momentary or latching (configurable via software)
Connector ...................................... (1) 3.5 mm captive screw connector, 3 pole
Contact rating ................................ 24 V, 1 A