Command
ASCII Command
(host to switcher)
Response
(switcher to host)
Additional
Description
Input Skew Adjustment
Set input skew
values
EX1&
*X1&*X1&ISEQ}
IseqX1&*X1&*X1&]
Set input skew values X1&
for R, G, and B signals
(IseqR*G*B).
Increment one input
skew value
EX1*
+ISEQ}
IseqX1&*X1&*X1&]
Increase the skew value
of X1* by 1.
Decrement one
input skew value
EX1*
-ISEQ}
IseqX1&*X1&*X1&]
Decrease the skew value
of X1* by 1.
View current values
E
ISEQ}
X1&
*X1&*X1&]
View skew values.
Output Skew Adjustment
Set output skew
values
EX1&
*X1&*X1&OSEQ}
OseqX1&*X1&*X1&]
Set output skew values
X1& for R, G, and B
signals (OseqR*G*B).
Increment one
output skew value
EX1*
+OSEQ}
OseqX1&*X1&*X1&]
Increase the skew value
of X1* by 1.
Decrement one
output skew value
EX1*
-OSEQ}
OseqX1&*X1&*X1&]
Decrease the skew value
of X1* by 1.
View current values
E
OSEQ}
X1&
*X1&*X1&]
View skew values.
Recall Presets
Recall preset
X1@
.
RprX1@]
Recall preset X1@ .
View Preset Ties
View preset video
tie
EX1@
*1*1VC}
X!•
Vid]
View the video input X!
tied as a preset.
View preset audio
tie
EX1@
*1*2VC}
X!•
Aud]
View the audio input X!
tied as a preset.
Naming Presets
Write preset name
EX1@
,nameNG}
NmgX1@,name]
Name preset X1@.
Read preset name
EX1@
NG}
name]
View name X1@.
NOTE:
• If preset is unassigned, name displays [unassigned].
• If preset is saved but not yet named, default is “Preset X1@”(where X1@ is the preset number).
• If user tries to name when preset is unassigned, unit responds with E11.
• If user tries to recall an unsaved preset, unit responds with E11.
• Invalid characters: ~ , @ = ‘ [ ] { } < > ” ; :| \ and ?.
Naming Inputs and Outputs
Write input name
EX1$
,nameNI}
NmiX1$,name]
Name input X1$.
Read input name
EX1$
NI}
name]
View input X1$ name.
Write output name
EX1%
,nameNO}
NmoX1%,name]
Name output X1%.
Read output name
EX1%
NO}
name]
View output X1% name.
NOTE:
X! = Input selection: 0-8, 0 = no connection
X1@ = Preset number: 1-8
X1$ = Inputs 1-8: 1-8 = program audio inputs, 9 = Mic 1 audio input, 10 = Mic 2 audio input
X1% = Output number: 1-4
X1& = Skew adjustment value: 0-31, in 2 ns increments (for example 31 = 62 ns)
X1* = Video plane: 0 = red, 1 = green, 2 = blue
MLS 608 D Series • SIS Programming and Control
73