beautypg.com

Operation, cont’d – Extron Electronics ISS 108 User Manual

Page 34

background image

Operation, cont’d

Integration Seamless Switcher • Operation

3-12

Advanced Configuration menu

Figure 3-13 is a flowchart that shows an overview of the Advanced Configuration
menu, the submenus, and the available settings.

10 sec.

10 sec.

10 sec.

Dissolve Speed

1.0 Second

Default

Cycle

Default

Cycle

Menu

Menu

Next

10 sec.

10 sec.

Video & Audio

Configuration

Test Pattern
Color Bars

Program Preview

Off Off

Blue Only Mode

<

Off

>

On

Edge Smoothing

<

Off

>

On

Menu

Output

Configuration

Menu

Advanced

Configuration

Menu

User Presets

Menu

Next

Exit Menu

Press Next to Exit

Menu

10 sec.

Auto Imaging

<

Off

>

On

Auto Memories

<

Off

>

On

Enhanced Mode

<

Off

>

On

Preview Switch Mode

Stay

<

Swap

>

Reset Unit?

Press and Hold

BLACK/MUTE

To Reset

10 sec.

Next

Set test pattern type
• Color Bars
• Crosshatch
• 4x4 crosshatch
• Grayscale
• Crop

• Alternating pixels
• Film aspect 1.78
• Film aspect 1.85
• Film aspect 2.35
• Ramp

Change this setting
with either Adjust knob.

Change this setting
with either Adjust knob.

Select a test pattern
with the Adjust knob.

Select preview/program
off/on with the Adjust
knob.

Select blue mode with
the Adjust knob.

Select edge smoothing
with the Adjust knob.

Output blue video
and sync only
Enhance edges

To reset the scaler, press and
hold the Black button until
the reset message appears.
*
Adjust knobs do not affect
this submenu.

Preview Blanking

Top Bottom
000 000

Select top blanking with
the Adjust knob.

Select bottom blanking
with the Adjust knob.

Program Blanking

Top Bottom
000 000

Select top blanking with
the Adjust knob.

Select bottom blanking
with the Adjust knob.

Next

Next

Next

Next

Next

Next

Next

Next

Next

Next

Select auto imaging
with the Adjust knob.

Select auto presets
with the Adjust knob.

RGB Delay

Preview 0.8 Seconds

Pixel Phase

Program Preview

016 016

10 sec.

10 sec.

10 sec.

10 sec.

PAL Film Mode

Input #2

<

Off

>

On

Next

Select an input.
Change this setting
with either Adjust knob.

10 sec.

10 sec.

10 sec.

If necessary, select
another input and
repeat.

2

2

Time of the dissolve
(Dissolve button)
0.1 – 5.0 seconds

Change this value with
either Adjust knob.

Change this value with
either Adjust knob.

Change both values
simultaneously with
either Adjust knob.

Figure 3-13 — Advanced Configuration menu flowchart