Command
ASCII Command
(host to scaler)
Response
(scaler to host)
Additional Description
Front panel security lockout (Executive Mode)
Enable
1X
Exe1]
Allow limited front panel adjustments only.
Disable
0x
Exe0]
Allow adjustments/selections to be made from front
panel.
View status
X
X%
]
Show mode status. (0= disabled, 1= enabled)
SDI field flip
Standard
73*0#
Flp 0]
Flip fields
73*1#
Flp 1]
View
73#
X%
]
(0= standard, 1= flipped)
Enhanced mode
Enable
52*1#
Enh
X%
]
Disable
52*0#
Enh
X%
]
View mode
52#
X%
]
(0= disabled, 1= enabled)
Refresh lock
Enable
77*1#
Rfl 1]
Disable
77*0#
Rfl 0]
View status
77#
X%
]
(0= disabled, 1= enabled)
Auto memory
Enable
1M
Aut1]
Disable
0M
Aut0]
View status
M
X%
]
(0= disabled, 1= enabled)
Aspect mode
Enable Fill mode
99*1#
Ful1]
Starts Fill mode.
Enable Follow mode
99*0#
Ful0]
Starts Follow mode.
View status
99#
X10(
]
(0= Follow, 1= Fill)
DVS 304
Settings saved for
Auto Memory
16 per input (64 total)
Aspect ratio
Film mode
H/V start
Phase
Total pixels
H/V active
H/V pan
Zoom
H/V size
Bright/cont
Detail
H/V position
Color/tint
NOTE: X%
= On/off
0 = off/disable, 1 = on/enable
X10(
= Aspect ratio
0 = Follow, 1 = Fill
DVS 304 Series • SIS Communication and Control