Extron Electronics DVS 304 Series User Guide User Manual
Page 49

Command
ASCII Command
(host to scaler)
Response
(scaler to host)
Additional Description
Front panel security lockout (Executive Mode)
Enable
1X
Exe1]
Allow limited front panel adjustments only.
Disable
0x
Exe0]
Allow adjustments/selections to be made from front
panel.
View status
X
X%
]
Show mode status. (0= disabled, 1= enabled)
SDI field flip
Standard
73*0#
Flp 0]
Flip fields
73*1#
Flp 1]
View
73#
X%
]
(0= standard, 1= flipped)
Enhanced mode
Enable
52*1#
Enh
X%
]
Disable
52*0#
Enh
X%
]
View mode
52#
X%
]
(0= disabled, 1= enabled)
Refresh lock
Enable
77*1#
Rfl 1]
Disable
77*0#
Rfl 0]
View status
77#
X%
]
(0= disabled, 1= enabled)
Auto memory
Enable
1M
Aut1]
Disable
0M
Aut0]
View status
M
X%
]
(0= disabled, 1= enabled)
Aspect mode
Enable Fill mode
99*1#
Ful1]
Starts Fill mode.
Enable Follow mode
99*0#
Ful0]
Starts Follow mode.
View status
99#
X10(
]
(0= Follow, 1= Fill)
DVS 304
Settings saved for
Auto Memory
16 per input (64 total)
Aspect ratio
Film mode
H/V start
Phase
Total pixels
H/V active
H/V pan
Zoom
H/V size
Bright/cont
Detail
H/V position
Color/tint
NOTE: X%
= On/off
0 = off/disable, 1 = on/enable
X10(
= Aspect ratio
0 = Follow, 1 = Fill
DVS 304 Series • SIS Communication and Control
44