X7@ = Input selection: 2 or 4

X7# = Input video format: 1 = composite, 2 = S-video, 3 = RGBcvS, 4 = YUVi, 5 = YUVp/HDTV,
6 = RGB scaled, 7 = RGB pass through, 8 = auto detect/YUV auto, 9 = SDI

NOTE: RGB pass-through is only on analog output for DVI models. The DVI output is

disabled for RGB pass-through.

X7$ = H start: 0 to 127 for video inputs; 0 to 255 for RGB and YUVp/HDTV inputs.

X7% = V start: 0 to 93 for video inputs; 0 to 255 for RGB and YUVp/HDTV inputs.

X7^ = Pixel phase: 1 to 31

X7& = Total pixels (+/- 512 of the default value for RGB, fixed for video)

X7* = Active pixels (+/- 512 of the default value for RGB, +/- 100 for video)

X7( = Active lines (+/- 256 of the default value for RGB, +/- 127 for video)

X8) = 0 = 4:3, or 1 = 16:9

X8! = Input standard: 0 = none, 1 = NTSC 3.58, 2 = PAL, 3 = NTSC 4.43, 4 = SECAM,
- = RGB or YUVp/HDTV

X8@ = internal temperature (in degrees Celsius)

X8$ = Text label/preset name:

up to 16 characters

X8% = Picture adjustment: 0 to 127

X8^ = H and V position (values depend on current output rate)

X8& = H and V size (values depend on current output rate)

X8* = Zoom (100 to 200%)

X8( = Pan (values depend on current output rate and zoom %)

X9) = Test pattern: 0 to 2

X9! = Output resolution:

1 = 640x480

10 = 1365x768

18 = 1080i

2 = 800x600

11 = 1365x1024

19 = 1080p

3 = 852x480

12 = 1366x768

20 = 1440x900

4 = 1024x768

13 = 1400x1050

21 = 1680x1050

5 = 1024x852

14 = 1600x1200

22 = 1280x800

6 = 1024x1024

15 = 480p

23 = 1080p Sharp

7 = 1280x768

16 = 576p

24 = 1920x1200

8 = 1280x1024

17 = 720p

25 =1080p CVT

9 = 1360x765

X9@ = Output refresh rate:

1 = 50 Hz

4 = 96 Hz

6 = 120 Hz

2 = 60 Hz

5 = 100 Hz

7 = 59.94 Hz

3 = 72 Hz (75 Hz for 1440x900, 24 Hz for 1080p)

X9# = Output polarity: 0 = H - / V -, 1 = H - / V +, 2 = H + / V -, 3 = H+/ V +

X9$ = Output sync format: 0 = RGBHV (default), 1 = RGBS, 2 = RGsB, 3 = Y, R-Y, B-Y

X9% = Memory presets: 1 to 3

X9^ = Input 4 presets: 1 to 128

X9& = Test pattern: 0 to 3

X9* = OSD display setup: 0 to 5 seconds in 1 second steps.

X9( = Auto image: 0 to 2

DVS 304 Series • SIS Communication and Control