Synchronizing the array, 28 chapter 5: raid configuration – Asus KFN5-Q/SAS User Manual
Page 135
5-28
Chapter 5: RAID configuration
3. Use the arrow key to select the disk you would want to configure as
hot spare, then move the cursor to the Hot Spr column. Press <+>,
<->, or
Press
Synchronizing the array
Synchronizing the array allows the utility to resynchronize data on the
mirrored disk in the array. This procedure is seldom required because data
synchronization is automatically done during manual operation.
To synchronize the array
1. Follow steps 1 ~ 3 of the section “Viewing Volume Properties” and
step 2 of the section “Managing hot spares”.
2. From the Manage Array screen, select Synchronize Spare, then press
Esc = Exit Menu F1/Shift+1 = Help
Space/+/- = Change Item C = Commit Changes
LSI Logic Config Utility v6.08.05.00 (2006.08.02)
Manage Hot Spare -- SAS1068
Identifier
LSILOGIC Logical Volume 3000
Type
IME
Scan Order
0
Size(MB)
51498
Status
Optimal
Slot Device Identifier Hot Drive Pred Size
Num
Spr Status Fail (MB)
0
SEAGATE ST373454SS
0003 [NO] Ok No 34331
1 SEAGATE ST373454SS 0003 [NO] Ok No 34331
2 SEAGATE ST373454SS 0003 [NO] Ok No 34331
3 SEAGATE ST373454SS 0003
[Yes]
Hot Spare No 35003
[----] --------- -- -----
Esc = Exit Menu F1/Shift+1 = Help
Enter = Select Item
LSI Logic Config Utility v6.08.05.00 (2006.08.02)
Manage Array -- SAS1068
Identifier
LSILOGIC Logical Volume 3000
Type
IME
Scan Order
0
Size (MB)
51498
Status
Optimal
Manage Hot Spare
Synchronize Array
Activate Array
Delete Array
3. Press