beautypg.com

Asus KFN5-Q/SAS User Manual

Page 127

background image

5-20

Chapter 5: RAID configuration

Esc = Exit Menu F1/Shift+1 = Help

SPACE/+/- = Select disk for array or hot spare C = Create array

LSI Logic Config Utility v6.08.05.00 (2006.08.02)

Create New Array Type -- SAS1068

M - Keep existing data, migrate to an IM array.

Synchronization of disk will occur.

D - Overwrite existing data, create a new IM array.

ALL DATA on ALL disk in the array will be DELETED!!

No Synchronization performed.

7. A confirmation screen appears.

Press to keep existing data on the first disk. If you choose this

option, data on the first disk will be mirrored on the second disk that

you will add to the volume later. Make sure the data you want to

mirror is on the first disk.

Press to overwrite any data and create the new IM array.

8. Repeat steps 5 and 6 to add the second disk to the volume.
9. When done, press to create the array, then select Save changes

then exit this menu.

10. The utility creates the array.

Create and save new array?

Cancel Exit
Save changes then exit this menu
Discard changes then exit this menu

Exit the Configuration Utility and Reboot

LSI Logic Config Utility v6.08.05.00 (2006.08.02)

Processing...may take up 1 minute

Creating RAID array