GigaX3112 Series Layer 3 Managed Switch

Figure 23. Spanning tree – Port Parameters

4.5.2 Link aggregation static

The page configures the link aggregation static group (port trunking). The switch

provides maximum 32 link aggregation groups. This maximum can be achieved

on stacking configuration. For standalone GX3112 or GX3112F, the maximum

group is 6 since it supplies 12 ports only and up to 8 ports per group.

Port Selection Criterion: the algorithm to distribute packets among the

ports of the link aggregation group according to source MAC address,

destination MAC address, source and destination MAC address, source IP

address, destination IP address, or source and destination IP address.
Trunk ID: a number to identify the trunk group besides the group name
Port: these port icons are listed the same way as on the front panel. You

have to click on the icon to select the group members. The port can be

removed from the group by clicking the selected port again.

Click

OK to make the setting send to the connected switch. Click Reload to

refresh the settings to current value. To make the configuration effective, go to

“Save Configuration” page, and click

Save.

You have to check the runtime link speed and duplex mode to make sure the

trunk is physically active. Go to Physical Interface and check the link mode in

the runtime status window for the trunk ports. If all the trunk members are in the

same speed and full duplex mode, then the trunk group is set up successfully.

If one of the members is not in the same speed or full duplex mode, the trunk

is not set correctly. Check the link partner and change the settings to have the

same speed and full duplex mode for all the members of your trunk group.

Edge Port: An edge port is the same as a Port Fast-enabled port, and you

should enable it only on ports that connect to a single end station.

Click

OK to effect the settings. Click Reload to refresh the settings to current value.