2 ordering – GE Industrial Solutions GERAPID 2607, 4207, 6007, 8007 with arc chutes 1X2, 1X4, 2X2, 2X3, 2X4 User Manual
Page 52

52
Design and specifications are subject to change without notice
S47183e rev.03 2010-06-07
7.2 Ordering.
Gerapid
with arc chute
APN460437 rev03 09/2009
Quantity
to
Diagram no:
Customer's reference no.
Opt
Code
Code
1
1
5
2
2
6
3
3
7
4
4
5
6
1
4
7
2
5
8
3
6
9
S
E
10
1
7
11
2
8
12
3
9
13
4
A
14
5
B
15
6
R
16
1
5
17
2
6
18
3
R
19
4
20
B
21
S
22
1
0
23
2
24
1
25
2
0
26
1
5
27
2
6
28
3
7
29
4
8
30
kA
kA
kA
kA
kA
kA
0
31
kA
kA
kA
kA
kA
kA
32
1
4
33
2
5
34
3
R
35
1
4
36
2
R
37
3
38
0
39
[KSM]: code 10
1
40
0
4
41
1
5
42
2
6
43
3
44
0
2
45
[EDA]: code 12
1
3
46
0
47
[ZWA]: code 13
1
48
0
49
[STA]: code 14
1
50
0
2
51
[SCH]: code 15
1
52
0
53
[HAN]: code 16
1
54
0
55
[LBM]: code 17
1
56
0
57
[ZAL]: code 18
1
58
1
3
59
2
4
60
[SST]: code 19
R
61
1
4
62
2
63
[CUS]: code 20
3
R
64
En
Ch
65
De
R
On Request
On Request
On Request
125 V AC
Unlock "On Request" options.
Breaker number:
Special ratings tested by customer.
2X3 (3000 V)
2X4 (3600 V)
EF4-12 (3600 V)
110 V AC
120 V AC
On request
Name
Gerapid 8007R
Gerapid 10007R
Gerapid 8007DS
Impulse coil with internal C-bank (NEKO)
-
Relevant standard
China acc. IEC947-2 & GB14048.2
Military type acc. MIL-C-5015G
English
Documentation Language
LV DC acc. IEEEC37.14
[LNG]:
Contact position indicator
ED impulse coil release
Without
With
With
With
Without
Without
Closing solenoid supply voltage
Without
5 convertible contacts
With
Without
9 convertible contacts
Forced tripping release
Without
Impulse coil w/o internal C-bank
With
Without
Sidewalls protection panels
Without
Rodent proofing
German
Catalogue no:
Arc chute type
[LIC]: code 2
1X4 (2000 V)
2X2 S (1500 V)
V/H
Fixed setting up to 15 kA
Ta = 35 °C
Top connector '-'
250 V DC
without SEL
Not apply
Heavy Industry type
LV DC acc. IEC60947-2
Standard Shunt Trip
Shunt Trip - external 220 V DC
Chinese
Mechanical Counter
Control connectors type
Railway & Industry applications
Counter
Gearapid SE retrofit
[POL]: code 5
SEL operation temperature
[TSEL]: code 6
OC release
Threshold [kA]
Auxiliary tripping releases
Shunt Trip - external 110 V DC
[STE]: code 3
Auxiliary contacts quantity
Without
[HIL]: code 11
OC trip target
[HIS]: code 9
Protection options
Lever for manual operating
Arc chute presence
Railway DC acc. EN50123-2
[KSA]: code 7
[NET]: code 8
Control circuits supply voltage
Requested marks on the scale
33 .. 85 V DC
Adjustable up to 15 kA
-
24 V/24 V (DC stabilizer)
Adjustable up to 24 kA
Fixed setting up to 24 kA
3 convertible contacts
Ta = 55 °C
external 24 V DC±5%
Polarized adj. 0,4 kA - 1,2 kA
Main terminals layout
Top/Bottom
Top connector '+'
Main terminals polarization
H/H - (H)orizontal
V/V
[ANS]: code 4
Polarized adjust. 0,8 kA - 2,5 kA
2X2 (2000 V)
Shunt Trip - external 125 V DC
88 .. 145 V DC
125 .. 353 V DC / 115 .. 240 V AC
10 convertible contacts
Gerapid 8007
60 V DC
48 V DC
220 V DC
110 V DC
125 V DC
1X2 (1000 V)
1X3 (1500 V)
Gerapid 4207
Name
Breaker type
Gerapid 2607
[BAU]: code 1
Code Name
Gerapid 6007
230 V AC
240 V AC
Special type B
Special type S
For SEL 6 kA
For SEL 12 kA
On Request
H/V - (V)ertical
On Request
Standard Zero Voltage Release
Without OCT
On Request
Polarized adjust. 2 kA - 6 kA
Polarized adjust. 4 kA - 8 kA
=>
=>
=>