5.9. EXAMPLE OFA BRICKS PROGRAM
Suppose that on the master the CFIX is programmed as follows:
Slave_id=27
Len_w
=
2
Fix_dst_md
=
12
Ind_ivar_src =4
Len_r=3
Fix src md =22
Ind_ivar_dst=88
This means that, if communication with slave 27 is established, the master will transmit 2 IVARs (4 and 5)
to FIX 12 and 13 of the slave, and will receive 3 FIX (22,23 and 24) of the slave in IVAR 88, 89 and 90 of
the master.
The slave program must use RFIX and WFIX. FIX 12 and 13 will be read (RFIX) and
FIX 88,89 and 90 will be
written. For example:
RFIXOInd_fix=12
RFIX 0 md_var
=
100
RFIX 0 Typqyar
=
3
RFIX 0
Tmo
=
xxx
RFIX1Ind_fix=13
RFIX1Ind_var= 101
RFIX 1
Typevar
=
3
REIX 1
Tmo
=
xxx
will copy FIX 12 and 13 in IVAR 100 and 101 (in the slave, no DeviceNet communication is involved) and:
WFIX 0
Ind_fix
=
22
WFIXOInd_var= 150
WFIX 0 Typevar
=
3
WFIX 0
Tmo
=
xxx
WFIX1Ind_fix=23
WFIX1Ind_var= 151
WFIX 1
Typevar
=
3
WFIX 1
Tmo
=
xxx
WFIX 2
md_fix =24
WFIX2Ind_var= 152
WFIX 2
Typevar
=
3
WFIX 2 Tmo
=
xxx
will copy IVAR 150,151 and 152 of the slave in FIX 22,23 and 24 (in the slave, no DeviceNet communication
is involved).
“‘U
HOW TO EXCHANGE 110 DATA
- EntelliGuard G Spring charge Contact (3 pages)
- Austin Lynx II SIP (19 pages)
- TLE Series 225-500 User Manual (90 pages)
- Power Mark Gold Generator Interlock Kit (2 pages)
- CAR2548FP series (15 pages)
- Spectra Series Power Panelboards AEG47 and AEG47S (1 page)
- GE TR7000 Series (17 pages)
- Record Plus Motor Operator Mechanism: FC100 (6 pages)
- Spectra Series Power Panelboards Endwall Kit (1 page)
- ProTrip Conversion Kits DB-75, DBL-75, DB-100, DBL-100 (16 pages)
- Spectra II Series Busway Plugs (2 pages)
- Spectra Series Power Panelboards AMC2GM and AMC3GM (2 pages)
- EntelliGuard 800–2000 A Frames, 240–600 Vac Maintenance Manual (64 pages)
- EntelliGuard G Ready To Close (4 pages)
- Position Switch Kit (12 pages)
- Spectra Series Power Panelboards AMCB4QD and AMCB6QD (4 pages)
- Record Plus TDR Door-Ring Interlock Kit: FC100 (4 pages)
- ProTrip Conversion Kits DB-15 (20 pages)
- Record Plus TDR, NEMA 1, 12: FE250 (5 pages)
- ATL010A0X43-SR (21 pages)
- Spectra Series Power Panelboards 30–200 Ampere Fusible Switch (2 pages)
- CAR2512FP Front-End (15 pages)
- CP2000AC54TE (20 pages)
- MX150_MX250 Modbus Network Card (27 pages)
- Spectra Series Power Panelboards 800 & 1200 Ampere Fusible Switch (2 pages)
- Spectra Series Fusible Switch Units J & T (4 pages)
- EntelliGuard G NETWORK INTERLOCK DEVICE (3 pages)
- EntelliGuard TU Trip Units (106 pages)
- ZBTSD Series (36 pages)
- AF-600 FP Profibus DP (91 pages)
- Neutral Mounting Kit - DNK400 (1 page)
- Record Plus Variable Depth Operating Mechanism: FE250 (4 pages)
- Spectra Series Power Panelboards 30–60 Ampere Expansion Kit (4 pages)
- Power Break II Undervoltage Release (4 pages)
- Record Plus Shunt Trip and Undervoltage Release (4 pages)
- EntelliGuard G Drawout Secondary Disconnect (4 pages)
- ACE4000T SERIES (2 pages)
- SPSA600 (12 pages)
- Dry-Type General Purpose Power Transformers (8 pages)
- Power Express Class 2 (8 pages)
- Austin MegaLynx (20 pages)
- CAR1612FP series (7 pages)
- H5692448 Power Systems Infinity M1 (NE-M) (76 pages)
- CAR2024FP series (7 pages)
- EBVW020A0B Barracuda Series (18 pages)