GE Industrial Solutions GPS4827 User Manual
Page 88

Galaxy Power System GPS4827
86
Cabinet Output -48V
1 or 2 x Full Height
Maximum System
Output Current
50 - 1800A
1800A @ 45
:C
Cabinet Mechanical
Full Height
Nominal Cabinet Dimensions
(H x W x D)
2134 H x 600 W x 600 D mm
(84 H x 23.6 W x 23.6 D in.)
Units Per Initial Cabinet
Rectifiers
1 - 36
Controller
1 per system
Battery Disconnect Modules
0 - 1
DC Distribution
1 – As many as will fit
Units Per Supplemental Cabinet
Rectifiers
1 – 12 (Maximum 36 rectifiers per system)
Battery Disconnect Modules
0 - 1
DC Distribution
1 – As many as will fit
Environmental
Operating Ambient
Temperature
0°C to +45°C
Altitude
-50 to 4000 meters
Note: For altitudes between 1500 and 4000 meters, derate the maximum
temperature by 0.656°C per 100 meters.
Humidity
5% to 95% non-condensing
Radiated and Conducted
Emissions
FCC Part 15, EN55022 (CISPR22), EN55024, Level A GR1089
Electromagnetic Immunity
Complies with GR1089
Earthquake Rating
Zone 4, upper floors
Standards Compliance
Agency Approvals
CE Marked, UL
Underwriters Laboratories (UL) 1950 Listed per Subject Letter S1801, DC Power
Distribution Centers for Telecommunications Equipment
- EntelliGuard G Spring charge Contact (3 pages)
- Austin Lynx II SIP (19 pages)
- TLE Series 225-500 User Manual (90 pages)
- Power Mark Gold Generator Interlock Kit (2 pages)
- CAR2548FP series (15 pages)
- Spectra Series Power Panelboards AEG47 and AEG47S (1 page)
- GE TR7000 Series (17 pages)
- Record Plus Motor Operator Mechanism: FC100 (6 pages)
- Spectra Series Power Panelboards Endwall Kit (1 page)
- ProTrip Conversion Kits DB-75, DBL-75, DB-100, DBL-100 (16 pages)
- Spectra II Series Busway Plugs (2 pages)
- Spectra Series Power Panelboards AMC2GM and AMC3GM (2 pages)
- EntelliGuard 800–2000 A Frames, 240–600 Vac Maintenance Manual (64 pages)
- EntelliGuard G Ready To Close (4 pages)
- Position Switch Kit (12 pages)
- Spectra Series Power Panelboards AMCB4QD and AMCB6QD (4 pages)
- Record Plus TDR Door-Ring Interlock Kit: FC100 (4 pages)
- ProTrip Conversion Kits DB-15 (20 pages)
- Record Plus TDR, NEMA 1, 12: FE250 (5 pages)
- ATL010A0X43-SR (21 pages)
- Spectra Series Power Panelboards 30–200 Ampere Fusible Switch (2 pages)
- CAR2512FP Front-End (15 pages)
- CP2000AC54TE (20 pages)
- MX150_MX250 Modbus Network Card (27 pages)
- Spectra Series Power Panelboards 800 & 1200 Ampere Fusible Switch (2 pages)
- Spectra Series Fusible Switch Units J & T (4 pages)
- EntelliGuard G NETWORK INTERLOCK DEVICE (3 pages)
- EntelliGuard TU Trip Units (106 pages)
- ZBTSD Series (36 pages)
- AF-600 FP Profibus DP (91 pages)
- Neutral Mounting Kit - DNK400 (1 page)
- Record Plus Variable Depth Operating Mechanism: FE250 (4 pages)
- Spectra Series Power Panelboards 30–60 Ampere Expansion Kit (4 pages)
- Power Break II Undervoltage Release (4 pages)
- Record Plus Shunt Trip and Undervoltage Release (4 pages)
- EntelliGuard G Drawout Secondary Disconnect (4 pages)
- ACE4000T SERIES (2 pages)
- SPSA600 (12 pages)
- Dry-Type General Purpose Power Transformers (8 pages)
- Power Express Class 2 (8 pages)
- Austin MegaLynx (20 pages)
- CAR1612FP series (7 pages)
- H5692448 Power Systems Infinity M1 (NE-M) (76 pages)
- CAR2024FP series (7 pages)
- EBVW020A0B Barracuda Series (18 pages)