GE Industrial Solutions CPS2400U User Manual
Page 43
CPS2400U Upstream System – 19” Product Manual
CPS2400U
850028186 r04 December 2013
43
Table 10 Alarm Reference Table
Controller
Alarm Card
Converter Card
Alarm Display
What it means
LED
State
Relay
State
Alarm
LED
State
Relay
State
OK
LED
State
Alarm
LED
State
Corrective Action
Input Power
A1-8 Power Fail
Yellow
Min
A Red
Min
Green
Off
Reconnect DC input
power flowing to the
A1-8 input terminal.
Input Power
B1-8 Power Fail
Yellow
Min
B Red
Min
Green
Off
Reconnect DC input
power flowing to the
B1-8 input terminal
Input Power
A9-16 Power
Fail
Yellow
Min
A Red
Min
Green
Off
Reconnect DC input
power flowing to the
A9-16 input terminal
Input Power
B9-16 Power
Fail
Yellow
Min
B Red
Min
Green
Off
Reconnect DC input
power flowing to the
B9-16 input terminal.
Input Power
Mul Circuit Fail
A1-8 & B1-8
Power Fail
Red
Maj
A Red
B Red
Maj
Green
Off
Reconnect DC input
power flowing to the
A1-8 input terminal
and Reconnect DC
input power flowing to
the B1-8 input terminal
Input Power
Mul Circuit Fail
A9-16 & B9-16
Power Fail
Red
Maj
A Red
B Red
Maj
Green
Off
Reconnect DC input
power flowing to the
A9-16 input terminal.
Reconnect DC input
power flowing to the
B9-16 input terminal.
Load Drop
Load Drop
Yellow
Min
A, B &
OK
Green
Green
Off
Check the integrity of
the circuits going to
the load. Or Adjust
load drop threshold to
0 to disable this
feature.
Load Share
As set of circuits
assigned to one
remote
destination are
not sharing
current as
would be
expected.
Yellow
Min
A, B &
OK
Green
Green
Off
Check the integrity of
the circuits going to
the load. Or Adjust
load share threshold to
disable this feature.
Line Test
OK, Fail or
Aborted
A, B &
OK
Green
Green
Off
Estimated line
resistance has
increased since last
measurement.
Loss Of
Redundancy
Yellow
Min
A, B &
OK
Green
Green
Off
The loss of n additional
circuits will cause
customers to lose
service. Check
redundancy threshold
in the configuration.