Table 1 System Troubleshooting
Controller
Alarm Card
Converter Card
Possible Problem
Possible Solution
Alarm Display
Back-
light
Relay
State
Alarm
LED
State
Relay
State
OK
LED
State
Alarm
LED
State
Circuit Fail
Yellow
Min
Yellow
Min
Flashing
Yellow
Under Voltage
Replace Converter.
Note: Replacing a Converter storing will interrupt
service to the other line served by the Converter.
Fan Fail
Yellow
Min
Yellow
Min
Green
Off
1 Fan Tray Failed
Replace fan shelf or tray.
Fan Fail
Yellow
Min
Yellow
Min
Green
Off
1 of 6 fans Failed on one
Fan Shelf or Tray
Replace fan shelf or tray.
Fan Fail
Red
Maj
Red
Maj
Green
Off
2 Fan Shelves or Trays
Failed
Replace fan shelves or trays.
Input Power
Yellow
Min
A Red
Min
Green
Off
A1-6 Power Fail
Restore DC input power to the A1-6 input terminal.
Input Power
Yellow
Min
B Red
Min
Green
Off
B1-6 Power Fail
Restore DC input power flowing to the B1-6 input
terminal
Input Power
Yellow
Min
A Red
Min
Green
Off
A7-12 Power Fail
Restore DC power to the A7-12 input terminal
Input Power
Yellow
Min
B Red
Min
Green
Off
B7-12 Power Fail
Restore DC power to the B7-12 input terminal.
Input Power
Mul Circuit Fail
Red
Maj
A Red
B Red
Maj
Green
Off
A1-6 & B1-6 Power Fail
Restore DC power to the A1-6 input terminal and
Restore DC power to the B1-6 input terminal
Input Power
Mul Circuit Fail
Red
Maj
A Red
B Red
Maj
Green
Off
A7-12 & B7-12 Power Fail Restore DC power to the A7-12 input terminal.
Restore DC power to the B7-12 input terminal.
Load Drop
Yellow
Min
A, B &
OK
Green
Green
Off
Load Drop
Check the integrity of the circuits going to the load.
Or Adjust load drop threshold to 0 to disable this
feature.
Load Share
Yellow
Min
A, B &
OK
Green
Green
Off
As set of circuits
assigned to one remote
destination are not
sharing current as would
be expected.
Check the integrity of the circuits going to the load.
Or Adjust load share threshold to disable this
feature.
Line Test
A, B &
OK
Green
Green
Off
OK, Fail or Aborted
Estimated line resistance has increased since last
measurement.
Loss Of
Redundancy
Yellow
Min
A, B &
OK
Green
Green
Off
The loss of n additional circuits will cause
customers to lose service.