beautypg.com

Save configuration, Rate control – B&B Electronics EIR508-T - Manual User Manual

Page 61

background image

Manual Documentation Number: EIR508-2xx-T 1713m

61

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com

B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com

Save Configuration

Save the configuration to flash memory. If the switch is powered off without

saving the configuration, all changed configuration will lost.

 Click

Save Flash

Save Configuration Interface

Rate Control

Set up every port

’s bandwidth rate and packet limitation type

Limit Packet type: Select the packet type to filter. The packet types

have are all packet types, broadcast/multicast/unknown unicast packets,

broadcast/multicast packets, and broadcast packet only. The

broadcast/multicast/unknown unicast packet, broadcast/multicast

packet, and broadcast packet only are only for ingress. The egress rate

only supports all packet types.

Band Width: Ports 1 through 8 support port ingress and egress rate

control. For example, assume port 1 is 10Mbps, users can set its

effective egress rate to 1Mbps, and the ingress rate to 500Kbps.

Ingress: Select the port effective ingress rate. The valid range

value is 1MB, 2MB, 4MB, 8MB, 16MB, 32MB and 64MB. The

default value is

“disable”

Egress: Select the port effective ingress rate. The valid range

value is 128kbps, 256Kbps, 512Kbps, 1MB, 2MB, 4MB, and 8MB.

The default value is

“disable.”

 Click

Apply