queue packets at the same time.
Use the strict priority scheme: The highest queue will always be
processed first.
Priority Type: Every port has 5 priority types
Port-base: The port priority will follow the default port priority
assigned
– High, middle, low, or lowest.
COS only: The port will follow the COS priority assigned.
TOS only: The port will follow the TOS priority assigned.
COS first: The port will follow COS priority first, and then another
priority rule.
TOS first: The port will follow TOS priority first, and then another
priority rule.
COS priority: Set the COS priority level 0~7
TOS priority: The system provides 0 to 63 TOS priority levels. Each
level has 4 types of priority
– high, mid, low, and lowest. The default
value is
“Lowest”. When the IP packet is received, the system will check
the TOS value.
[NOTE] QoS and Rate control cannot be used simultaneously.