beautypg.com

B&B Electronics SPP-100 - Manual User Manual

Page 19

background image

2.2.1.4 Example 4

SPP100EN.EXE (e,s0,b278,i5,wd8)

In example 4, the Enabler will configure the SPP-100 in socket 0 with a
base address of 278H and IRQ 5 using a configuration memory window at
segment D800. The SPP-100 will operate in EPP compatible printer port
mode and the BIOS equipment list will not be updated.

2.2.1.5 Example 5

SPP100EN.EXE (s0,b3BC,i5,r)

In example 5, the Enabler will release the configuration used by the
SPP-100 in socket 0 using a configuration memory window at segment
D000. The base address and IRQ parameters are ignored and may be
omitted.

2.2.1.6 Example 6

SPP100EN.EXE (s1,r,wcc)

In example 6, the Enabler will release the configuration used by the
SPP-100 in socket 1 using a configuration memory window at segment
CC00.

SPP-100 User's Manual

2-11