beautypg.com

B&B Electronics SPP-100 - Manual User Manual

Page 17

background image

2.2.1 Command Line Options

To configure a SPP-100 in the system, the Enabler requires one command
line argument from the user to determine the configuration of the card.
This argument must be enclosed in parenthesis and within the argument,
any or all of the following parameters may be specified using a comma
(no spaces)

to separate each parameter:

Ssocket

specifies which PCMCIA socket the SPP-100 must be inserted
into for this configuration argument to be used. socket must be
in the range 0 - 15. This option is always required.

Baddress

specifies the base I/O address of the SPP-100 in hexadecimal
and must reside on an even 8-byte boundary. This option is
required if the 'R' option is not used.

Iirq

specifies the interrupt level (IRQ) of the SPP-100 in decimal.
irq

must be one of the following values: 3, 4, 5, 7, 9, 10, 11, 12,

14, 15, or 0 if no IRQ is desired. This option is required if the
'R' option is not used.

Waddress specifies the base address of the memory window required to

configure the SPP-100. Set address = D0 for a memory window
at segment D000, address = D8 for a memory window at
segment D800, etc. Valid settings for address are C8, CC, D0,
D4, D8, and DC. If this option is omitted, a memory window
at segment D000 will be used.

Emode

specifies EPP mode operation for the SPP-100 (This overrides
the mode selection bit in the Extended Control Register.). If
this option is omitted, the SPP-100 defaults to standard printer
port mode operation.

Llist

specifies that the enabler update the BIOS equipment when the
enabler is executed. The enabler, however, can not remove the
SPP-100 from the BIOS equipment when the card is removed
or when the enabler is executed with the 'R' option. If this
option is omitted, the BIOS equipment list is not updated.

SPP-100 User's Manual