Ra01, Control commands, Configuration setting command – Rainbow Electronics RA01 User Manual
Page 10
![background image](/manuals/281058/10/background.png)
RA01
Version: 1.0 Date: 10/8/2008
Control Commands
Control Word
Related Parameters/Functions
Related control bits
1
Configuration Setting Command
Frequency band, crystal oscillator load
capacitance, baseband filter bandwidth, etc.
b1 to b0, eb, et, x3 to x0,
i2 to i0. dc
2
Frequency Setting Command
Frequency of the local oscillator
f11 to f0
3
Receiver Setting Command
VDI source, LNA gain, squelch, enable receiver
d1 to d0, g1 to g0, sq, en
4
Wake-up Timer Command
Wake-up time period
r3 to r0, m7 to m0
5
Extended Wake-up Timer Command
Wake-up time period finer adjustment
d1 to d0, m13 to m8
6
Low Battery Detector
and Clock Divider Command
LBD voltage and microcontroller clock division
ratio
d2 to d0, elfc, t3 to t0
7
Data Filter Command
Data filter type, clock recovery parameters, POR
level selection, autosleep mode
al, ml, dsfi, sf, ewl, srt, r1
to r0
8
Data Rate Command
Bit rate
cs, r6 to r0
9
Output and FIFO Command
FIFO IT level, FIFO start control, FIFO enable
and FIFO fill enable
f3 to f0, s1 to s0, ff, fe
10
Extended Features Command
Low frequency output clock, wake-up timer extra
functions, long FIFO extra functions
exlp, ctls, dcal, bw1 to
bw0, f5 to f4
11
Low Duty Cycle Command
Duty Cycle operation
d6 to d0, enld
12
Demodulator Setting Command
Demodulator time constant
tc1, tc0
13
Status Read Command
Receiver status read
Note: In the following tables the POR column shows the default values of the command registers after power-on.
1. Configuration Setting Command
bit
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
POR
1
0
0
b1
b0
eb
et
ex
x3
x2
x1
x0
i2
i1
i0
dc
938Ah
x3
x2
x1
x0
Crystal Load
Capacitance [pF]
0
0
0
0
8.5
0
0
0
1
9.0
0
0
1
0
9.5
0
0
1
1
10.0
… …
0
0
0
0
15.5
0
0
0
0
16.0
b1
b0
Frequency Band [MHz]
0
0
Reserved
0
1
434
1
0
868
1
1
915
i2
i1
i0
IF Frequency
[kHz]
Baseband
Bandwidth [kHz]
0
0
0
Reserved
Reserved
0
0
1
245
340
0
1
0
230
260
0
1
1
180
200
1
0
0
145
140
1
0
1
105
105
1
1
0
Reserved
Reserved
1
1
1
Reserved
Reserved
Bits eb and et control the operation of the low battery
detector and wake-up timer, respectively. They are
enabled when the corresponding bit is set.
If ex is set the crystal is active during non-active
mode. When dc bit is set it disables the clock output.
Note: The wake-up timer can be enabled by the
elfc
bit in the Low Battery Detector and Microcontroller Clock
Divider Command or by the
enldc
bit in the Low Duty Cycle Command or by enabling the low battery detector by
eb
bit in this command.
Tel: +86-755-82973805 Fax: +86-755-82973550 E-mail: [email protected] http://www.hoperf.com