Figure #50 – Grain Systems PNEG-366 User Manual
Page 42
Grain Systems, Inc. Assumption, Ill.
42
18' Autoflow
OverFlow Level Switch
TAF-6103
5
30º Roof Panel
Figure #50
3
4
1
2
Key
Part No.
Description
Quantity
Weight
1
TD-100076
Rotary Switch Power-Pak
1
3.50
2
TD-100627
Roof Mount Coupling Weldment
1
2.14
3
TD-100075
Flex-Coupling
1
0.50
4
S-7241
1/8" x 1.1/4" Cotter Pin
2
0.02
5
TAF-6086
3-Vane Paddle
1
0.75
*
TAF-6097
Hardware Package
1
0.98
--
PNEG-300
Rotary Switch Instructions
1
0.04
--
S-275
5/16" - 18 x 3/4" Bin Bolt
6
0.16
--
S-3651
Tube Seal
1
0.74
--
S-396
5/16" - 18 Hex Nut
6
0.06
--
S-7241
1/8" x 1.1/4" Cotter Pin
2
0.02
REV. 11-20-96
* Hardware Package not
shown
-
Included in Hardware
Package
INSTALLATION OF OPTIONAL ROOF-MOUNTED LEVEL SWITCHES
Attach flex-coupling to the power-pak and install roll pin. Apply teflon tape or pipe sealant (not included) to power-
pak pipe threads and thread power-pak into mounting plate coupling. Conduit opening in power-pak should be at right
angles to roof rib or face toward eave.
Caulk underside of mounting plate above and both sides of 2" hole. Bolt to roof panel.