Assembly

Power Supply of the Rotational Laser Level

Operation with Batteries/Rechargeable Batteries
Using alkali-manganese or rechargeable batteries is recom-

mended for operation of the measuring tool.
To open the battery compartment 14, turn the locking knob

15 to position

and pull out the battery compartment.

When inserting the batteries/rechargeable batteries, pay at-

tention to the correct polarity according to the representation

on the inside of the battery compartment.
Always replace all batteries/rechargeable batteries at the

same time. Do not use different brands or types of batter-

ies/rechargeable batteries together.
Shut the battery compartment 14 and turn the locking knob

15 to the position.
In case the batteries/rechargeable batteries have been insert-

ed incorrectly, the measuring tool cannot be switched on. In-

sert the batteries/rechargeable batteries with correct polarity.
f

Remove the batteries/rechargeable batteries from the

measuring tool when not using it for longer periods.

When storing for longer periods, the batteries/rechargea-

ble batteries can corrode and discharge themselves.

Operation with Battery Pack
Charge the battery pack 13 before using for the first time. The

battery pack can only be charged with the battery charger 22

intended for it.
f

Observe the mains voltage! The voltage of the power

source must correspond with the data on the type plate of

the battery charger.

Insert the appropriate mains plug 23 for your mains supply

into the battery charger 22 and allow it to engage.
Insert the charge plug 24 of the battery charger into the

socket connector 17 of the battery pack. Connect the battery

charger to the mains supply. Charging the empty battery pack

takes approx. 14 h. The battery charger and the battery pack

are protected against overcharging.
A battery that is new or has not been used for a longer period

does not develop its full capacity until after approx. 5 charg-

ing/discharging cycles.
Do not charge the battery pack 13 each time after using, oth-

erwise its capacity will be reduced. Charge the battery pack

only when the charge-control indicator 12 flashes or lights up

continuously.
A considerably reduced operating period after charging indi-

cates that the battery pack is used up and must be replaced.
If the battery pack is empty, the measuring tool can also be

operated off of the battery charger 22 when connected to a

power supply. Switch the measuring tool off, charge the bat-

tery pack for approx. 10 min and then switch the measuring

tool on again with the battery charger connected.
To change the battery pack 13, turn the locking knob 16 to

position

and pull out the battery pack 13.

Insert a new battery pack and turn the locking knob 16 to the

position.

f

Remove the battery pack from the measuring tool

when not using it for longer periods. When storing for

longer periods, the rechargeable batteries can corrode

and discharge themselves.

Charge-control Indicator
When the charge-control indicator 12 flashes red for the first

time, the measuring tool can still be operated for approx. 2 h.
When the charge-control indicator 12 lights up red continu-

ously, measurements are no longer possible. The measuring

tool switches off automatically after 1 minute.

Power Supply of the Remote Control

Using alkali-manganese batteries is recommended for opera-

tion of the remote control.
To open the battery lid 34, press the latch 33 in the direction

of the arrow and remove the battery lid. Insert the battery pro-

vided. When inserting, pay attention to the correct polarity

according to the representation on the inside of the battery

compartment.
f

Remove the battery from the remote control when not

using it for longer periods. When storing for longer peri-

ods, the battery can corrode and discharge itself.

Battery Charger

Article number

2 610 A13 782

Rated voltage

V~

100–240

Frequency

Hz

50/60

Output voltage

V=

7.5

Charging current

A

1.0

Allowable charging tempera-

ture range

°C

0–45

Charging time

h

14

Number of battery cells

2

Rated voltage (per battery cell)

V=

1.2

Weight according to

EPTA-Procedure 01/2003

kg

0.2

Protection class

/II

Remote control

RC 1

Professional

Article number

3 601 K69 900

Working range

3)

30 m

Operating temperature

–10 °C...+50 °C

Storage temperature

–20 °C...+70 °C

Battery

1 x 1.5 V LR06 (AA)

Weight according to

EPTA-Procedure 01/2003

69 g

3) The working range can be decreased by unfavourable environmental
conditions (e.g. direct sun irradiation).
Please observe the article number on the type plate of your remote con-
trol. The trade names of individual remote controls may vary.
For clear identification of your remote control, see the serial number 32
on the type plate.