beautypg.com

York YZB018 THRU 060 User Manual

Page 5

background image

271457-YTG-B-0908

Johnson Controls Unitary Products

5

COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils

UNIT MODEL

FURNACE

COIL

MODEL

COOLING

CFM RANGE

(MIN.-MAX.)

W

RATED

CFM

NET MBH

SEER

1

EER

TOTAL

SENS.

YZB01811

450
750

14,17

FC/MC/PC/UC18

600

18.0

13.2

13.00

11.00

14

HC18

600

18.0

13.2

13.00

11.00

-

HD24

600

18.0

13.2

13.00

11.00

YZB02411

600

1000

14,17

FC/MC/PC/UC24

800

22.8

16.7

13.00

11.00

14,17

FC/MC/PC/UC30

800

22.8

16.7

13.00

11.00

14

HC30

800

22.8

16.7

13.00

11.00

-

HD24

800

22.4

17.8

13.00

11.00

YZB03011

800

1200

14,17,21

FC/MC/PC/UC36

1000

29.2

21.3

13.00

11.00

17

HC36

1000

29.6

21.0

13.00

11.00

-

HD36

1000

29.6

21.6

13.00

11.00

YZB03611

1000
1400

14,17,21

FC/MC/PC/UC36

1200

34.4

25.7

13.00

11.00

17

HC36

1200

35.2

25.7

13.00

11.00

-

HD36

1200

34.8

26.1

13.00

11.00

YZB04211

1200
1600

21,24

FC/MC/PC/UC48

1400

41.0

31.8

13.00

11.00

21

HC42

1400

40.0

30.7

13.00

11.00

-

HD48

1400

40.0

31.2

13.00

11.00

YZB04811

1400
1800

21,24

FC/MC/PC/UC60

1600

46.0

34.3

13.00

11.00

24

HC60

1600

46.0

33.5

13.00

11.00

-

HD60

1600

46.0

33.2

13.00

11.00

24

MC61

1600

46.5

34.9

13.00

11.00

YZB06012

1600 - 2000

24

FC/MC62D

1800

54.0

40.0

13.00

11.00

1. Requires a 2FD06700224 Blower Time Delay unless a standard furnace is equipped with one.