CP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the
total electric power input during the same period.

HEATING CAPACITY - YZB01811With Variable Speed Furnaces

VARIABLE

SPEED

FURNACE

COIL

1

MODEL

ARI HEATING

2

47

°F

17

°F

HSPF

MBH

COP

KW

MBH

COP

KW

STD

13 SEER HP WITH VARIABLE SPEED FURNACES

3

PV8*A12

FC/MC/PC18A

18.0

3.46

1.52

11.1

2.46

1.32

8.35

PV9*A12

FC/MC/PC18A

18.0

3.42

1.54

11.2

2.42

1.36

8.30

P(C,V)9*B12

FC/MC/PC18B

18.0

3.46

1.52

11.1

2.46

1.32

8.35

Y*(8,L)C*A12

FC/MC/PC18A 19.5 3.52 1.62 11.2 2.44 1.35 8.30

Y*(8,L)C*B12

FC/MC/PC18B 19.5 3.46 1.65 11.2 2.44 1.35 8.30

Y*9C*B12

FC/MC/PC18B 19.5 3.52 1.62 11.2 2.44 1.35 8.30

Y*(8,L)C*A12

FC/MC/PC24A 19.6 3.70 1.55 10.9 2.64 1.21 8.30

Y*(8,L)C*B12

FC/MC/PC24B 19.5 3.64 1.57 10.8 2.62 1.21 8.40

Y*9C*B12

FC/MC/PC24B 19.6 3.72 1.54 10.8 2.66 1.19 8.30

Y*(8,L)C*A12

FC/MC/PC30A 19.6 3.70 1.55 10.9 2.64 1.21 8.30

Y*(8,L)C*B12

FC/MC/PC30B 19.5 3.64 1.57 10.8 2.62 1.21 8.40

Y*9C*B12

FC/MC/PC30B 19.6 3.72 1.54 10.8 2.66 1.19 8.30

Y*(8,L)C*A12

HC18

19.5 3.52 1.62 11.2 2.44 1.35 8.30

Y*(8,L)C*A12

HD24

19.5 3.48 1.64 10.7 2.44 1.29 8.30

Y*(8,L)C*B12

HD24

19.4 3.36 1.69 10.7 2.38 1.32 8.30

Y*9C*B12

HD24

19.5 3.50 1.63 10.7 2.44 1.29 8.30

Y*(8,L)C*A12

UC18A

19.6 3.58 1.60 11.0 2.54 1.27 8.30

Y*(8,L)C*B12

UC18B

19.5 3.52 1.62 11.0 2.50 1.29 8.30

Y*9C*B12

UC18B

19.5 3.58 1.60 11.0 2.54 1.27 8.30

Y*(8,L)C*A12

UC24A

19.6 3.74 1.54 10.9 2.66 1.20 8.30

Y*(8,L)C*B12

UC24B

19.5 3.66 1.56 10.8 2.64 1.20 8.30

Y*9C*B12

UC24B

19.6 3.76 1.53 10.8 2.68 1.18 8.30

Y*(8,L)C*A12

UC30A

19.6 3.74 1.54 10.9 2.66 1.20 8.30

Y*(8,L)C*B12

UC30B

19.5 3.66 1.56 10.8 2.64 1.20 8.30

Y*9C*B12

UC30B

19.6 3.76 1.53 10.8 2.68 1.18 8.30

G*9V*A12

FC/MC/PC18A 19.6 3.48 1.65 11.3 2.42 1.37 8.20

G*9V*B12

FC/MC/PC18B 19.5 3.52 1.62 11.2 2.44 1.35 8.30

G*9V*A12

FC/MC/PC24A 19.6 3.64 1.58 11.1 2.58 1.26 8.30

G*9V*B12

FC/MC/PC24B 19.6 3.72 1.54 10.8 2.66 1.19 8.30

G*9V*A12

FC/MC/PC30A 19.6 3.64 1.58 11.1 2.58 1.26 8.30

G*9V*B12

FC/MC/PC30B 19.6 3.72 1.54 10.8 2.66 1.19 8.30

G*9V*A12

HC18

19.6 3.48 1.65 11.3 2.42 1.37 8.20

G*9V*A12

HD24

19.6 3.42 1.68 10.8 2.40 1.32 8.20

G*9V*B12

HD24

19.5 3.50 1.63 10.7 2.44 1.29 8.30

G*9V*A12

UC18A

19.6 3.56 1.61 11.1 2.52 1.29 8.30

G*9V*B12

UC18B

19.5 3.58 1.60 11.0 2.54 1.27 8.30

G*9V*B12

UC24B

19.6 3.76 1.53 10.8 2.68 1.18 8.30

G*9V*A12

UC30A

19.7 3.68 1.57 11.1 2.60 1.25 8.30

G*9V*B12

UC30B

19.6 3.76 1.53 10.8 2.68 1.18 8.30

1. Rated CFM same as for cooling.
2. Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no

supplemental electric heat operation.

3. Variable speed furnaces have B.O.D (Blower on Delay) standard.