York YZB018 THRU 060 User Manual
Page 13

271457-YTG-B-0908
Johnson Controls Unitary Products
13
CP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the
total electric power input during the same period.
— = Not Applicable.
HEATING PERFORMANCE - With Air Handler
UNIT
MODEL*
AIR
HANDLER
COIL
1
MODEL
ARI HEATING
2
47
°F
17
°F
HSPF
MBH
COP
KW
MBH
COP
KW
STD
1 PH 13 SEER HP WITH MA
YZB01811
MA08B
FC/M
C18B
18.0
3.28
1.61
11.6
2.32
1.46
8.00
YZB02411
MA08B
FC/MC24B
24.0
3.44
2.04
14.2
2.38
1.75
8.00
MA08B
FC/MC30B
24.0
3.44
2.04
14.2
2.38
1.75
8.00
YZB03011
MA12B
FC/MC36B
30.0
3.44
2.56
18.3
2.28
2.35
8.00
YZB03611
MA12B
FC/MC36B
36.0
3.36
3.14
24.4
2.32
3.08
8.00
YZB04211
MA16C
FC/MC48C
42.0
3.66
3.36
28.4
2.54
3.28
8.00
MA14D
FC/MC48D
42.0
3.66
3.36
28.4
2.54
3.28
8.00
YZB04811
MA16C
FC60C
48.0
3.50
4.10
33.2
2.30
4.23
8.00
MA20D
FC/MC60D
48.0
3.50
4.10
33.2
2.30
4.23
8.00
MA20D
MC61D
48.0
3.50
4.10
33.2
2.30
4.23
8.00
YZB06012
MA20D
FC/MC62D
57.0
3.54
4.77
37.0
2.44
4.49
8.55
1 PH 13 SEER HP WITH MV - VARIABLE SPEED
YZB01811
MV12B
FC/MC18B
18.0
3.46
1.52
11.1
2.46
1.32
8.35
YZB02411
MV12B
FC/MC24B
23.4
3.44
1.99
14.2
2.38
1.75
8.30
MV12B
FC/MC30B
23.4
3.44
1.99
14.2
2.38
1.75
8.30
YZB03011
MV12B
FC/MC36B
29.4
3.44
2.50
18.3
2.28
2.35
8.20
MV16C
FC/MC36C
29.4
3.44
2.50
18.3
2.28
2.35
8.20
YZB03611
MV12B
FC/MC36B
36.0
3.36
3.14
24.4
2.32
3.08
8.30
YZB04211
MV16C
FC/MC48C
42.0
3.66
3.36
28.4
2.54
3.28
8.60
MV20D
FC/MC48D
42.0
3.66
3.36
28.4
2.54
3.28
8.60
YZB04811
MV16C
FC/MC60C
48.0
3.50
4.02
33.2
2.30
4.23
8.10
MV20D
FC/MC60D
48.0
3.50
4.02
33.2
2.30
4.23
8.10
MV20D
MC61D
48.0
3.50
4.02
33.2
2.30
4.23
8.10
YZB06012
MV20D
FC/MC62D
56.0
3.56
4.65
37.0
2.48
4.37
8.65
1 PH 13 SEER HP WITH AV / SV / F*FV - VARIABLE SPEED
YZB01811
AV24
–
18.0
3.42
1.54
11.2
2.24
1.46
8.25
YZB02411
AV24
–
23.2
3.68
1.85
13.5
2.28
1.73
8.25
YZB03011
AV36
–
29.2
3.66
2.34
17.6
2.20
2.34
8.15
YZB03611
AV36
–
36.0
3.36
3.14
24.4
2.32
3.08
8.30
AV/SV48
–
36.0
3.50
3.01
23.6
2.26
3.06
8.30
YZB04211
AV/SV48
–
42.0
3.82
3.22
27.8
2.48
3.28
8.20
YZB04811
AV/SV48
–
48.0
3.60
3.91
32.6
2.26
4.23
8.10
F*FV060
–
48.0
3.50
4.23
33.2
2.30
4.23
8.10
1 PH 13 SEER HP WITH AHP / SHP / F*FP
YZB01811
AHP18
–
18.0
3.28
1.61
11.6
2.32
1.46
8.00
F*FP024
–
18.0
3.30
1.77
11.5
2.32
1.45
8.05
YZB02411
AHP24
–
24.0
3.44
2.04
14.2
2.38
1.75
8.00
F*FP030
–
23.8
3.44
2.03
14.2
2.38
1.75
8.00
YZB03011
AHP30
–
30.0
3.44
2.56
18.3
2.28
2.35
8.00
AHP36
–
30.0
3.44
2.56
18.3
2.28
2.35
8.00
F*FP036
–
29.6
3.44
2.52
18.3
2.28
2.35
8.00
YZB03611
AHP36
–
36.0
3.36
3.14
24.4
2.32
3.08
8.00
AHP42
–
36.0
3.36
3.14
24.4
2.32
3.08
8.00
F*FP036
–
36.0
3.36
3.23
24.4
2.32
3.08
8.00
F*FP042
–
36.0
3.36
3.23
24.4
2.32
3.08
8.00
YZB04211
AHP/SHP48
–
42.0
3.66
3.36
28.4
2.54
3.28
8.00
YZB04811
AHP/SHP48
–
48.0
3.50
4.10
33.2
2.30
4.23
8.00
AHP/SHP60
–
48.0
3.50
4.10
33.2
2.30
4.23
8.00
1. Rated CFM same as for cooling.
2. Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no
supplemental electric heat operation.