York YZB018 THRU 060 User Manual

Page 14

background image

271457-YTG-B-0908

14

Johnson Controls Unitary Products

CP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the
total electric power input during the same period.
— = Not Applicable.

HEATING PERFORMANCE - Upflow Furnace Coils

UNIT

MODEL*

COIL

1

MODEL

ARI HEATING

2

47

°F

17

°F

HSPF

MBH

COP

KW

MBH

COP

KW

STD

YZB01811

FC/MC/PC/UC18

18.0

3.28

1.61

11.6

2.32

1.46

8.00

HC24

18.0

3.28

1.61

11.6

2.32

1.46

8.00

HD24

18.0

3.28

1.61

11.6

2.32

1.46

8.00

YZB02411

FC/MC/PC/UC24

24.0

3.44

2.04

14.2

2.38

1.75

8.00

FC/MC/PC/UC30

24.0

3.44

2.04

14.2

2.38

1.75

8.00

HC30

24.0

3.44

2.04

14.2

2.38

1.75

8.00

HD24

24.0

3.44

2.04

14.2

2.38

1.75

8.00

YZB03011

FC/MC/PC/UC36

30.0

3.44

2.56

18.3

2.28

2.35

8.00

HC36

30.0

3.44

2.56

18.3

2.28

2.35

8.00

HD36

30.0

3.44

2.56

18.3

2.28

2.35

8.00

YZB03611

FC/MC/PC/UC36

36.0

3.36

3.14

24.4

2.32

3.08

8.00

HC36

36.0

3.36

3.14

24.4

2.32

3.08

8.00

HD36

36.0

3.36

3.14

24.4

2.32

3.08

8.00

YZB04211

FC/MC/PC/UC48

42.0

3.66

3.36

28.4

2.54

3.28

8.00

HC48

42.0

3.66

3.36

28.4

2.54

3.28

8.00

HD48

42.0

3.66

3.36

28.4

2.54

3.28

8.00

YZB04811

FC/MC/PC/UC60

48.0

3.50

4.10

33.2

2.30

4.23

8.00

HC60

48.0

3.50

4.10

33.2

2.30

4.23

8.00

HD60

48.0

3.50

4.10

33.2

2.30

4.23

8.00

MC61

48.0

3.50

4.10

33.2

2.30

4.23

8.00

YZB06012

FC/MC62D

57.0

3.54

4.77

37.0

2.44

4.49

8.55

1. Rated CFM same as for cooling.
2. Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no

supplemental electric heat operation.