CP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the
total electric power input during the same period.
HEATING CAPACITY - YZB04811With Variable Speed Furnaces
VARIABLE
SPEED
FURNACE
COIL
1
MODEL
ARI HEATING
2
47
°F
17
°F
HSPF
MBH
COP
KW
MBH
COP
KW
STD
1 PH 13 SEER HP WITH VARIABLE SPEED FURNACES
P(C,V)9*D20
FC/MC/PC60D
48.0
3.54
3.97
32.8
2.32
4.14
8.50
PV8*C20
FC/PC60C
48.0
3.50
4.02
33.2
2.30
4.23
8.00
P(C,V)9*C20
FC/PC60C
48.0
3.52
4.00
33.0
2.32
4.17
8.50
PV8*C20
HC60
48.0
3.50
4.02
33.2
2.30
4.23
8.00
P(C,V)9*D20
HC60
48.0
3.50
4.02
33.2
2.30
4.23
8.00
PV8*C20
HD60
48.0
3.50
4.02
33.2
2.30
4.23
8.00
P(C,V)9*D20
HD60
48.0
3.50
4.02
33.2
2.30
4.23
8.00
P(C,V)9*D20
MC61D
48.0
3.54
3.97
32.8
2.32
4.14
8.50
Y*9C*D20
FC/MC/PC60D 47.5 3.48 4.00 33.0 2.28 4.24 8.00
Y*9C*D20
FC/MC62D
48.0 3.54 3.97 32.8 2.30 4.18 8.10
Y*(8,L)C*C16
FC/PC60C
47.5 3.50 3.98 33.0 2.30 4.21 8.00
Y*(8,L)C*C20
FC/PC60C
47.5 3.54 3.93 32.8 2.32 4.14 8.10
Y*9C*C16
FC/PC60C
47.5 3.48 4.00 33.2 2.28 4.27 8.00
Y*9C*C20
FC/PC60C
47.5 3.48 4.00 33.2 2.28 4.27 8.00
Y*(8,L)C*C16
HD60
47.0 3.30 4.17 32.6 2.14 4.46 7.90
Y*(8,L)C*C20
HD60
47.0 3.32 4.15 32.4 2.16 4.40 7.90
Y*9C*C16
HD60
47.0 3.26 4.23 32.6 2.12 4.51 7.90
Y*9C*C20
HD60
47.0 3.26 4.23 32.6 2.12 4.51 7.90
Y*9C*D20
HD60
47.0 3.28 4.20 32.6 2.14 4.46 7.90
Y*(8,L)C*C16
UC60C
47.5 3.56 3.91 32.6 2.32 4.12 8.10
Y*(8,L)C*C20
UC60C
47.5 3.62 3.85 32.4 2.36 4.02 8.10
Y*9C*C16
UC60C
48.0 3.54 3.97 32.8 2.30 4.18 8.10
Y*9C*C20
UC60C
48.0 3.54 3.97 32.8 2.30 4.18 8.10
Y*9C*D20
UC60D
48.0 3.54 3.97 32.8 2.32 4.14 8.10
G*9V*D20
FC/MC/PC60D 47.5 3.48 4.00 33.0 2.28 4.24 8.00
G*9V*D20
FC/MC62D
48.0 3.54 3.97 32.8 2.30 4.18 8.10
G*9V*C16
FC/PC60C
47.5 3.48 4.00 33.2 2.28 4.27 8.00
G*9V*C20
FC/PC60C
47.5 3.48 4.00 33.2 2.28 4.27 8.00
G*9V*C16
HD60
47.0 3.26 4.23 32.6 2.12 4.51 7.90
G*9V*C20
HD60
47.0 3.26 4.23 32.6 2.12 4.51 7.90
G*9V*D20
HD60
47.0 3.28 4.20 32.6 2.14 4.46 7.90
G*9V*C16
UC60C
48.0 3.54 3.97 32.8 2.30 4.18 8.10
G*9V*C20
UC60C
48.0
3.54 3.97 32.8 2.30 4.18 8.10
G*9V*D20
UC60D
48.0 3.54 3.97 32.8 2.32 4.14 8.10
Notes listed below.
HEATING CAPACITY - YZB06012With Variable Speed Furnaces
VARIABLE
SPEED
FURNACE
COIL
1
MODEL
ARI HEATING
2
47
°F
17
°F
HSPF
MBH
COP
KW
MBH
COP
KW
STD
1 PH 13 SEER HP WITH VARIABLE SPEED FURNACES
P(C,V)9*D20
FC/MC62D
55 3.54 4.55 37 2.46 4.35 8.65
Y*(8,L)C*C20
FC/MC62D
56.5 3.56 4.65 34.0 2.40 4.15 8.10
Y*9C*C20
FC/MC62D
57.0 3.50 4.77 34.2 2.36 4.25 8.00
Y*9C*D20
FC/MC62D
57.0 3.50 4.77 34.0 2.38 4.19 8.10
G*9V*C20
FC/MC62D
57.0 3.50 4.77 34.2 2.36 4.25 8.00
G*9V*D20
FC/MC62D
57.0 3.50 4.77 34.0 2.38 4.19 8.10
1. Rated CFM same as for cooling.
2. Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no