York YZB018 THRU 060 User Manual
Page 29
271457-YTG-B-0908
Johnson Controls Unitary Products
29
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed
temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
COOLING PERFORMANCE DATA
OUTDOOR UNIT MODEL NO.
YZB04211
INDOOR COIL MODEL NO.
FC/MC/PC/UC48
CONDENSER
ENTERING AIR
TEMPERATURE
ID CFM
1200
1400
1600
ID DB (°F)
80
80
75
80
80
80
80
75
80
80
80
80
75
80
80
ID WB (°F)
57
62
62
67
72
57
62
62
67
57
57
62
62
67
72
65
T.C.
41.7
43.4
41.3
47.3
50.7
44.2
44.8
42.6
48.5
50.4
46.8
46.3
44.0
49.8
50.1
S.C.
38.3
36.4
31.1
30.9
24.9
40.5
40.1
33.1
33.6
26.0
42.8
43.8
35.0
36.3
27.0
K.W.
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
2.6
75
T.C.
40.0
41.2
39.4
44.8
47.5
42.3
42.8
40.5
46.0
47.5
44.7
44.4
41.7
47.2
47.4
S.C.
36.7
35.5
29.9
29.9
23.4
38.8
38.5
31.9
32.5
24.6
40.8
41.6
34.0
35.0
25.9
K.W.
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
3.0
85
T.C.
38.3
39.1
37.5
42.4
44.4
40.4
40.8
38.4
43.5
44.6
42.5
42.6
39.3
44.6
44.8
S.C.
35.2
34.5
28.6
29.0
21.9
37.0
37.0
30.8
31.4
23.3
38.8
39.5
33.0
33.8
24.7
K.W.
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
3.3
95
T.C.
36.7
36.9
35.6
40.0
41.3
38.5
38.9
36.3
41.0
41.7
40.4
40.8
37.0
42.0
42.1
S.C.
33.6
33.5
27.3
28.0
20.4
35.2
35.4
29.7
30.3
21.9
36.8
37.3
32.0
32.6
23.5
K.W.
3.6
3.6
3.6
3.6
3.7
3.7
3.6
3.6
3.6
3.7
3.7
3.6
3.6
3.6
3.7
105
T.C.
35.5
34.9
33.2
37.5
38.9
36.3
36.6
33.8
38.4
39.3
37.1
38.4
34.5
39.3
39.7
S.C.
32.5
31.7
26.3
27.1
19.9
33.2
33.4
28.3
29.4
21.5
33.9
35.1
30.4
31.6
23.0
K.W.
4.2
4.1
4.1
4.1
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
4.2
115
T.C.
34.4
33.0
30.9
35.0
36.5
34.2
34.5
31.4
35.8
36.9
34.0
36.0
32.0
36.7
37.3
S.C.
31.5
30.0
25.2
26.2
19.4
31.2
31.5
27.0
28.4
21.0
31.0
33.0
28.8
30.7
22.6
K.W.
4.7
4.6
4.6
4.6
4.7
4.6
4.6
4.6
4.7
4.7
4.6
4.7
4.6
4.7
4.7
125
T.C.
33.3
31.0
28.6
32.6
34.1
32.1
32.3
29.1
33.3
34.5
30.8
33.6
29.5
34.0
34.9
S.C.
30.4
28.3
24.2
25.2
19.0
29.3
29.5
25.8
27.5
20.5
28.1
30.8
27.3
29.8
22.1
K.W.
5.1
5.1
5.1
5.1
5.2
5.1
5.1
5.1
5.1
5.2
5.1
5.2
5.1
5.2
5.2
NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.
Air Handler
Coil
T.C.
S.C.
KW
MA16C
FC/MC48C
1.00
1.00
1.00
MA14D
FC/MC48D
1.00
1.00
1.00
MA16C
FC60C
1.00
1.00
1.00
MV16C
FC/MC48C
1.02
1.02
0.96
MV20D
FC/MC48D
1.02
1.02
0.96
AHP/SHP48
–
1.00
1.00
1.00
AV/SV48
–
1.01
1.02
0.96
–
HC42
0.98
0.96
1.00
–
HD48
0.98
0.98
1.00
Variable Speed
Furnace
Coil
T.C.
S.C.
KW
PV8*C16
FC/MC/PC48C
1.00
0.90
1.01
PV8*C20
FC/MC/PC48C
1.00
0.90
1.03
P(C,V)9*C16
FC/MC/PC48C
1.00
0.90
1.03
P(C,V)9*C20
FC/MC/PC48C
1.00
0.90
1.01
P(C,V)9*D20
FC/MC/PC48D
1.00
0.90
1.03
Y*(8,L)C*C16 FC/MC/PC48C 1.02
1.03
0.96
Y*(8,L)C*C20 FC/MC/PC48C 1.02
1.03
0.96
Y*9C*C16 FC/MC/PC48C
1.01
1.03
0.97
Y*9C*C20 FC/MC/PC48C
1.01
1.02
0.98
Y*9C*D20 FC/MC/PC48D
1.02
1.03
0.97
Y*(8,L)C*B12
HD48
0.99 0.97 0.98
Y*(8,L)C*C16
HD48
1.02 1.02 0.96
Y*(8,L)C*C20
HD48
1.02 1.02 0.95
Y*9C*B12
HD48
0.97 0.91 0.95
Y*9C*C16
HD48
0.99 0.99 0.97
Y*9C*C20
HD48
0.99 0.99 0.97
Y*9C*D20
HD48
1.02 1.02 0.97
Y*(8,L)C*C16
UC48C
1.01 1.03 0.96
Y*(8,L)C*C20
UC48C
1.01 1.03 0.96
Y*9C*C16
UC48C
1.00 1.02 0.97
Y*9C*C20
UC48C
1.00 1.02 0.98
Y*9C*D20
UC48D
1.00 1.02 0.97
G*9V*C16
FC/MC/PC48C
1.01 1.03 0.97
G*9V*C20
FC/MC/PC48C
1.01 1.02 0.98
G*9V*D20
FC/MC/PC48D
1.02 1.03 0.97
G*9V*B12
HD48
0.97 0.91 0.95
G*9V*C16
HD48
0.99 0.99 0.97
G*9V*C20
HD48
0.99 0.99 0.97
G*9V*D20
HD48
1.02 1.02 0.97
G*9V*C16
UC48C
1.00 1.02 0.97
G*9V*C20
UC48C
1.00 1.02 0.98
G*9V*D20
UC48D
1.00 1.02 0.97
Variable Speed
Furnace
Coil
T.C.
S.C.
KW