York YZB018 THRU 060 User Manual

Page 20

background image

271457-YTG-B-0908

20

Johnson Controls Unitary Products

CP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the
total electric power input during the same period.

HEATING CAPACITY - YZB04211With Variable Speed Furnaces

VARIABLE

SPEED

FURNACE

COIL

1

MODEL

ARI HEATING

2

47

°F

17

°F

HSPF

MBH

COP

KW

MBH

COP

KW

STD

1 PH 13 SEER HP WITH VARIABLE SPEED FURNACES

PV8*C16

FC/MC/PC48C

42.0

3.66

3.36

28.4

2.54

3.28

8.00

PV8*C20

FC/MC/PC48C

42.0

3.66

3.36

28.4

2.54

3.28

8.00

P(C,V)9*C16

FC/MC/PC48C

42.0

3.74

3.29

28.0

2.58

3.18

8.60

P(C,V)9*C20

FC/MC/PC48C

42.0

3.76

3.27

28.0

2.60

3.16

8.60

P(C,V)9*D20

FC/MC/PC48D

42.0

3.74

3.29

28.0

2.58

3.18

8.60

PV8*C20

HC48

42.0

3.66

3.36

28.4

2.54

3.28

8.00

P(C,V)9*C20

HC48

42.0

3.66

3.36

28.4

2.54

3.28

8.00

PV8*C20

HD48

42.0

3.66

3.36

28.4

2.54

3.28

8.00

P(C,V)9*C20

HD48

42.0

3.66

3.36

28.4

2.54

3.28

8.00

Y*(8,L)C*C16

FC/MC/PC48C 41.5 3.80 3.20 28.0 2.62 3.13 8.10

Y*(8,L)C*C20

FC/MC/PC48C 41.5 3.82 3.18 27.8 2.64 3.09 8.20

Y*9C*C16

FC/MC/PC48C 41.5 3.78 3.22 28.0 2.60 3.16 8.10

Y*9C*C20

FC/MC/PC48C 42.0 3.76 3.27 28.2 2.60 3.18 8.10

Y*9C*D20

FC/MC/PC48D 41.5 3.78 3.22 28.0 2.62 3.13 8.10

Y*(8,L)C*B12

HD48

41.0 3.32 3.62 27.2 2.30 3.47 7.80

Y*(8,L)C*C16

HD48

41.0 3.46 3.47 27.0 2.36 3.35 7.90

Y*(8,L)C*C20

HD48

40.5 3.48 3.41 26.8 2.36 3.33 7.90

Y*9C*B12

HD48

40.0 3.16 3.71 27.0 2.24 3.53 7.80

Y*9C*C16

HD48

41.0 3.40 3.53 27.6 2.32 3.49 7.90

Y*9C*C20

HD48

41.0 3.38 3.56 27.6 2.32 3.49 7.90

Y*9C*D20

HD48

41.0 3.44 3.49 27.0 2.34 3.38 7.90

Y*(8,L)C*C16

UC48C

42.0 3.90 3.16 28.0 2.68 3.06 8.20

Y*(8,L)C*C20

UC48C

42.0 3.94 3.12 28.0 2.70 3.04 8.20

Y*9C*C16

UC48C

42.0 3.88 3.17 28.2 2.66 3.11 8.20

Y*9C*C20

UC48C

42.0 3.86 3.19 28.2 2.64 3.13 8.20

Y*9C*D20

UC48D

42.0 3.90 3.16 28.0 2.66 3.09 8.20

G*9V*C16

FC/MC/PC48C 41.5 3.78 3.22 28.0 2.60 3.16 8.10

G*9V*C20

FC/MC/PC48C 42.0 3.76 3.27 28.2 2.60 3.18 8.10

G*9V*D20

FC/MC/PC48D 41.5 3.78 3.22 28.0 2.62 3.13 8.10

G*9V*B12

HD48

40.0 3.16 3.71 27.0 2.24 3.53 7.80

G*9V*C16

HD48

41.0 3.40 3.53 27.6 2.32 3.49 7.90

G*9V*C20

HD48

41.0 3.38 3.56 27.6 2.32 3.49 7.90

G*9V*D20

HD48

41.0 3.44 3.49 27.0 2.34 3.38 7.90

G*9V*C16

UC48C

42.0 3.88 3.17 28.2 2.66 3.11 8.20

G*9V*C20

UC48C

42.0 3.86 3.19 28.2 2.64 3.13 8.20

G*9V*D20

UC48D

42.0 3.90 3.16 28.0 2.66 3.09 8.20

1. Rated CFM same as for cooling.
2. Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no

supplemental electric heat operation.